Maintenance
Air Filter
102
9831/7750-1
102
5. Identify the air filter.
6. Disconnect the scavenge hose from the cover and remove the cover.
7. Remove outer element.
8. If necessary, remove the inner element.
8.1. You must not tap or knock the element.
9. Clean the inside of cover and canister.
10. Carefully insert the new inner element into the canister.
11. Make sure it seats correctly and check the seal is fully seated.
12. Insert a new outer element into the canister, check seal is fully seated.
13. Put the cover and assemble the scavenge hose.
14. Push the cover firmly into position and make sure it is secured.
15. Check all hoses for condition and tightness.
15.1. Never try to replace hose with any other pipe/ hose. The machine can catch fire if incorrect parts are
fitted. Contact JCB service dealer for details.
Dust Valve
Check (Condition)
•
Check the dust valve for rips/tears.
•
Check there are no obstructions.
•
Check that the dust valve is free of dirt and dust.
•
Check that the dust valve securely attached to the air filter housing.
Summary of Contents for CT160