C8
MAINTENANCE
9803/1250
C8
Issue 1
BREAKER ASSEMBLY - STANDARD AND VIBRO-DAMPED (cont’d)
6
Treat thread of safety screw
V
with Loctite 242
and fit the safety screw into the head.
8
For vibro-damped handle breakers only
, fit the
remaining handle assembly. Treat the thread of
pivot pin
Z
with Loctite 242 and fit the pin. Spray
the handles, trigger and all contacting parts with a
suitable lubricant.
10 For standard handle breaker only
, fit the handles
to the top cover with capscrews. Torque tighten
the capscrews (see
Introduction section
).
7
For vibro-damped handle breakers only
, fit the
handle assembly springs. Fit the handle assembly
furthest from the trigger pin complete with pivot
pin into the handle bracket (see
Step 14 of
Dismantling
).
9
For vibro-damped handle breakers only
,
assemble the top cover onto the handle bracket.
Treat the threads of the top cover capscrews with
Loctite 242 and torque tighten (see
Introduction
section
).
11
Fit the housing spool
H
and housing seal
G
into
the head. Fit a new ‘O’ ring to the housing seal.