When preparing the unit for use (ignition and wood loading), it is important that the damper is in the
open position. While the unit is functioning ensure the damper is in the open position. Once the fire has
extinguished, close the damper.
Combustion air settings
The combustion air control is located on the base below the fireplace shelf. This mechanism controls
flow of air entering the firebox, which allows for a more precise control of the fire. The quantity of
combustion air entering the firebox can be altered by moving the combustion air control from the left
(low) to the right (high).
4. opeRation & Maintenance
open
posi
tion
not in USe
in USe
Cl
osed
posi
tion
slow Combustion
When the air combustion control is nearly closed, the fireplace is in its slowest combustion phase. If
the fire is hot enough, slow combustion will not stop the fire, but there will be a noticeable change in the
flame pattern. the flames will be slow and may appear dirty if the wood is too wet (moisture content of
15% and more). this method of operation is not recommended and will produce excessive creosote in
the fireplace and the flue.
Creosote may also accumulate on the glass panels.
Caution
: continuous and intensive slow burn operation may cause early deterioration of the appliance
and it’s components, as well as a chimney fire if the flue has not been regularly cleaned.
establisHing tHe first fire
Before establishing the first fire, remove all labels or equipment parts located in the ash box or in the
furnace. open the flue damper control.
While building your first fire, keep the combustion rate at a moderate level to ensure that the sealant
binds with the paint. all materials should be seasoned.
please note:
Before building a big fire, establish several fires. The curing process is necessary to ensure
that the paint is not damaged and that the insert is well seasoned.
Do not overload the furnace. the optimum amount of fuel should not exceed one third of the insert
volume. Before reloading, make sure that the fire has subsided. This will keep the fireplace from over-
firing.
flow of air can be regulated by the primary air controls at the front of the unit.
Except for the short time required to build a fire, the fireplace door should be fully closed. If doors are left
partly open, flue gas may be drawn out of the opening creating risks from both fire and smoke.
4. opeRation & Maintenance
operation & user guide (Continued)
operation & user guide (Continued)
ignition instruCtions (continued)
After an extended time of non-use, it is recommended that the firebox be checked and cleaned by a
professional to ensure there is no obstruction in the flue and no blocking of the manoeuvring members
(damper) before ignition.
aCCelerated Combustion
The maximum heat output for JC Bordelet fireplaces is achieved with the combustion air control fully
opened. The fireplace can achieve an optimal heat output with two large or three medium size pieces of
wood.
medium Combustion
This is the recommended mode for operating JC Bordelet fireplaces as it will deposit the least amount
of creosote on glass panels and in the flue. the combustion air control should be set to half-open after
ignition. The most efficient setting will vary depending on many factors including flue length and the
moisture content of the wood. Two large or three medium size pieces of wood should be burning over a
bed of hot coals.
important
Ventilation devices which operate with the fireplace on the same premises or on the premises which
share the same ventilation shaft may not function properly.
Please ensure the grate is never blocked.
During installation please allow for access to have the fireplace and the connecting shaft cleaned.
If required, install cut-off and stifling devices.
reCommended fuel
This fireplace is designed for wood fuel only. Any fuel other than wood is strictly forbidden.
as a general rule it is recommended; use dry, well-seasoned
Hard wood
with a 15% moisture content or
less in order for the unit to burn effectively and avoid any tarring. the heating output of wood depends on
the moisture percentage.
DiRectLY cUt
3 MontHS
6 MontHS
9 MontHS
75%
48%
37%
36%
78%
62%
46%
38%
33%
18%
16%
15%
35%
27%
24%
24%
1 YeaR
1 1/2 YeaR
2 YeaRS
2 1/2 YeaRS
C
C
l
l
C: Chunks l: logs
aVerage WooD Drying tiMe BaseD on Moisture Content
note:
The flue damper must be opened while the fireplace is in operation. The flue damper must only
be closed when the fireplace is not in operation.