grease gun fails to pump grease:
1.
Unscrew the purge valve without removing it, un
-
til all air has escaped.
2.
Tight the purge valve.
3.
Connect the flexible hose and depress the varia
-
ble speed trigger switch for 10–20 seconds.
4.
If grease fails to flow through the hose, repeat
from step 1.
NOTE! This tool has been tested at the factory,
which may result in a small amount of grease left
in the grease tube and hose assembly. It is recom-
mended to purge the tool with the brand of grease
to be used before first use.
OPERATION
LED work light
The LED light located on the front end will be activated
when the trigger switch is pressed to illuminate the im
-
mediate work surface.
Luz LED
Interruptor
de disparo
Trigger switch lock-off button
•
To lock the trigger switch, press the lock-off bu
-
tton.
•
To unlock the trigger switch, press the lock-off
button again.
NOTE! The lock-off button is open to indica
-
te when the switch is in its unlocked position.
Botón de bloqueo
Turning On/Off
•
To turn the tool on, depress the trigger switch.
•
To turn it off, release the trigger switch.
Grease flow rate adjustment wheel
The grease output flow rate can be adjusted to 8 di
-
fferent gears (1-8) by means of the speed adjustment
wheel:
NOTE: The seal resembles a cup, which should
open toward the top cap when prepared for suction
and filler pump filling.
4.
Reinsert the grease tube rod back into the grea
-
se tube.
Suction filling from a bulk container
1.
Put the open end of the grease tube assembly
into the bulk lubricant.
2.
Slowly pull back the grease tube handle to suc
-
tion the lubricant into the grease gun.
NOTE: Be sure to keep the open end of the
grease tube assembly far enough into the lu-
bricant to prevent air pockets in the grease
tube.
3.
When the grease tube rod is fully extended, se
-
cure it into the retaining slot
4.
Remove the grease gun tube assembly from the
bulk lubricant and wipe off excess grease.
5.
Screw the grease gun tube assembly back into
the grease gun.
6.
Release the grease tube rod from the retaining
slot and slowly press it back into the tube.
7.
Use the purge valve to bleed off any air that may
be trapped in the cartridge.
Filling the tool from the low-pressure filler pump
1.
Pull back on the grease gun tube handle slowly
and rotate the rod until it is secure in place. Do
not lock the rod into the retaining slot.
2.
Connect the low-pressure fitting on the grease
gun to the appropriate low-pressure fitting on the
filler pump. These fittings DO NOT lock together.
This prevents the grease gun cartridge from be
-
ing over filled.
3.
Fill until the rod is pushed out of the grease tube
approximately 8” (20 cm).
Do not overfill. If the rod
fails to move during the
filling process, stop. This
indicates that the rod is
not connected to the plun
-
ger and step one must be
repeated before procee
-
ding.
4.
Rotate the rod to release
and carefully push rod
back into the grease tube.
5.
Use the purge valve to
bleed off any air that may
be trapped in the cartrid
-
ge.
Purging air pockets
You must eliminate air pockets after each refill or if the
LED light
Switch