JBL Professional, 8500 Balboa Blvd, Northridge, CA 91329 Rev A- -06/2020
Figure 13
Figure 14 (0°)
Figure 15 (15°)
Step 15:
Re-attach the Side-Panel External Trim
Cover Panels to the side plates of the
speaker using the same 8-32x1/2
”
trusshead screws. Apply Loctite
Threadlocker Blue 242 or equivalent to
screws before re-attaching (
Refer to VLA-
C Series users guide).
Step 16:
Check all screws and attachment
connections before hoisting speaker
cluster.
VLA-C-SB2 for VLA-C-125S
Subwoofer Suspension
Step 17.
Remove the Side-Panel External Trim
Cover Panels from the speaker
(Refer to VLA-C Series users guide).
Hold onto the screws for later use.
Step 18:
Attach the (VLA-C-SB2) bracket on
the VLA-C125S Subwoofer using the
provided M10 hex bolts, flat washers,
and split lock washers.
(Figure 14 = 0°)
(Figure 15 = 15°)
(Figure 16 = 30°)
(Figure 17 = 45°)
Warning:
Do not use 90° bracket setting when
VLA-C125S is at the top of the array.
Step 19:
Tighten screws permanently.
Reference Torque = 30-35 ft/lb