Installation Guide

For SF12Mi and SF15i Models Only

Part Number: 351940-001

Summary of Contents for SoundFactor SF12Mi

Page 1: ...Installation Guide For SF12Mi and SF15i Models Only Part Number 351940 001...

Page 2: ...e product modification or neglect damage occur ring during shipment damage resulting from failure to follow instructions contained in your Instruction Manual damage resulting from the performance of r...

Page 3: ...in this manual are carefully followed Improper installation may result in damage injury or death The working load limit WLL of any JBL SoundFactor Install loudspeaker is maintained as long as no more...

Page 4: ...5 x 35 mm shoulder eye bolts with appropriate ratings and certified standards compliance for use in overhead suspension appli cations To install the eyebolts into the provided threaded holes on the lo...

Page 5: ...termination is identified as swaged Flemish eye terminations with heavy thimbles and certification tags If sling lengths cannot be predetermined and slings must be fabricated on site the suggested te...

Page 6: ...lude Quick Link Used in line with only one wire rope per end Only use load rated quick links which will have the WLL imprinted on the component Screw Pin Anchor Shackle Used in line or at an angle up...

Page 7: ...and method of attachment must be carried out in the manner specified by the Professional Engineer Improper installation may result in damage injury or death The following renderings represent some of...

Page 8: ...grade 8 or B7 fasteners Wire Rope Sling standard sling and SPA shackle OSR Fitting concrete anchors Angle Beam Wood Beam Round Beam Concrete Beam Mounting Plate standard custom concrete anchors with...

Page 9: ...Neutrik Speakon NL 4 x1 1 4 TS phone jack x1 parallel Enclosure Construction 19 mm 3 4 in MDF Medium Density Fiberboard with glued and mechanically fastened joint detail covered in black carpet Grill...

Page 10: ...Connectors Parallel Neutrik Speakon NL 4 x1 1 4 TS phone jack x1 Enclosure Construction 19 mm 3 4 in MDF Medium Density Fiberboard with glued and mechanically fastened joint detail covered in black ca...

Page 11: ...n 394 mm 22 7 in 577 mm O 45 in 11 4 mm 1 8 in 45 7 mm 12 7 in 323 mm 8 4 in 213 mm SF12Mi 27 2 in 691 mm 2x 2 4 in 60 9 mm 17 in 432 mm 18 5 in 470 mm 13 8 in 351 mm 3 8 in 96 5 mm 8 9 in 226 mm 5 4...

Page 12: ...epair or replacement of the deteriorated component s must be completed before anyone other than some one performing the repair is allowed access to the vicinity of the unsafe condition Note The workin...