Inspection, Maintenance and Liability

Suspension systems are comprised of mechanical devices and, as such, they require regular inspection and routine main-
tenance to ensure that safety has not been compromised. The JBL SoundFactor Install loudspeakers and associated sus-
pension components must be inspected for fatigue at least annually and immediately following exposure to impact,
mechanical shock, fire, water or other hazard. The inspection must include a visual survey of all corners and load bearing
surfaces for signs of cracking, water damage, de-lamination, and any other condition that may decrease the strength of
the loudspeaker enclosure or associated suspension components. The forged shoulder eyebolts provided with the JBL
SoundFactor Install loudspeakers must be inspected for fatigue at least annually. The inspection must include a visual sur-
vey of the material for signs of corrosion, bending or any other condition that may decrease the strength of the fastener.
Additionally, the eyebolts must be checked for possible spin-out of the enclosure. For all other hardware and fittings, refer
to the hardware manufacturer's inspection and maintenance guidelines for process. Should any signs of unsafe conditions
be observed, repair or replacement of the deteriorated component(s) must be completed before anyone other than some-
one performing the repair is allowed access to the vicinity of the unsafe condition.

Note:

The working load limit (WLL) of the JBL SoundFactor Install loudspeakers includes; a design factor equivalent to or 
exceeding ASME B30.20, VBG70, VBG9a and the manufacturer's proprietary performance standard.

All implied warranties, including warranties of merchantability and fitness for particular purpose, are limited in duration to
the length of the warranty. JBL's liability shall in no event exceed the cost of any defective product and shall not include
incidental or consequential damages of any kind, even if JBL has been advised of the possibility. Some states do not allow
limitations on how long certain warranties last and/or do not allow exclusion of incidental or consequential damages, so
the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

JBL is not responsible for the application of its products for any purpose or the misuse of this information for any purpose.
Furthermore, JBL is not responsible for the abuse of its products caused by avoiding compliance with inspection and main-
tenance procedures or any other abuse.

Allen Products

ATM Fly-Ware

(562) 424-1100

(888) RIG-MORE / (310) 834-5914

1635 E. Burnett Street

2100 South Wilmington Avenue

Signal Hill, CA 90806

Carson, CA 90810

www.allenproducts.com

www.atmflyware.com

M.A.N. Flying Systems

McMaster Carr

20 Sidar Road

Various locations through the United States.

Brook Road Industrial estate

For a location near you, visit them online at 

Rayleigh, Essex SS6 7XF 

www.mcmaster.com 

www.manfly.co.uk

JBL Professional - Tech Note V1 No. 14
“Basic Principles For Suspending Loudspeakers”
www.jblpro.com/technote/tn_v1n14.pdf

Resources

Summary of Contents for SoundFactor SF12Mi

Page 1: ...Installation Guide For SF12Mi and SF15i Models Only Part Number 351940 001...

Page 2: ...e product modification or neglect damage occur ring during shipment damage resulting from failure to follow instructions contained in your Instruction Manual damage resulting from the performance of r...

Page 3: ...in this manual are carefully followed Improper installation may result in damage injury or death The working load limit WLL of any JBL SoundFactor Install loudspeaker is maintained as long as no more...

Page 4: ...5 x 35 mm shoulder eye bolts with appropriate ratings and certified standards compliance for use in overhead suspension appli cations To install the eyebolts into the provided threaded holes on the lo...

Page 5: ...termination is identified as swaged Flemish eye terminations with heavy thimbles and certification tags If sling lengths cannot be predetermined and slings must be fabricated on site the suggested te...

Page 6: ...lude Quick Link Used in line with only one wire rope per end Only use load rated quick links which will have the WLL imprinted on the component Screw Pin Anchor Shackle Used in line or at an angle up...

Page 7: ...and method of attachment must be carried out in the manner specified by the Professional Engineer Improper installation may result in damage injury or death The following renderings represent some of...

Page 8: ...grade 8 or B7 fasteners Wire Rope Sling standard sling and SPA shackle OSR Fitting concrete anchors Angle Beam Wood Beam Round Beam Concrete Beam Mounting Plate standard custom concrete anchors with...

Page 9: ...Neutrik Speakon NL 4 x1 1 4 TS phone jack x1 parallel Enclosure Construction 19 mm 3 4 in MDF Medium Density Fiberboard with glued and mechanically fastened joint detail covered in black carpet Grill...

Page 10: ...Connectors Parallel Neutrik Speakon NL 4 x1 1 4 TS phone jack x1 Enclosure Construction 19 mm 3 4 in MDF Medium Density Fiberboard with glued and mechanically fastened joint detail covered in black ca...

Page 11: ...n 394 mm 22 7 in 577 mm O 45 in 11 4 mm 1 8 in 45 7 mm 12 7 in 323 mm 8 4 in 213 mm SF12Mi 27 2 in 691 mm 2x 2 4 in 60 9 mm 17 in 432 mm 18 5 in 470 mm 13 8 in 351 mm 3 8 in 96 5 mm 8 9 in 226 mm 5 4...

Page 12: ...epair or replacement of the deteriorated component s must be completed before anyone other than some one performing the repair is allowed access to the vicinity of the unsafe condition Note The workin...