17
=8
8
JBL ProFlora Count
bubble counter
9
Anti-rust
JBL ProFlora SafeStop
non-return valve
10 CO
2
passive reactor
JBL ProFlora Taifun
11
TopStop CO
2
hose
JBL ProFlora T3
12
CO
2
permanent test
JBL Test Set permanent CO
2
plus pH
12.1 Step by step installation
1.
For the
m
601 –
m
603 and
m
1003 sets first attach the extensions to the JBL Taifun
CO
2
Passive Reactor (10) according to the height of the aquarium. Rinse the reactor in
lukewarm water and place it vertically in the aquarium in a location with a slight current of
water. The upper edge should be approx. 2 cm under the surface of the water. The slits
of the individual modules should be as clear as possible from obstruction by plants or
decorations.
2.
Cut off the CO
2
hose (11) with scissors about 20 cm from the upper end of the reactor and
plug the free ends of the hose onto the hose supports of the non-return valve (9). Check
the direction of flow.
3.
Install the CO
2
permanent test (12) in the aquarium according to the enclosed
instructions.
4.
Select a suitable place to fit the bubble counter, where it can be easily observed. Install
the bubble counter (8). The bubble counter can either be attached using suction pads
(e.g. to the outside of the aquarium) or to a wall or surface of a piece of furniture with the
enclosed screws. Cut the CO
2
hose to the correct length and attach the free ends to the
hose screw connections of the bubble counter. Check that the supply hose is attached
to the connection with the long pipe in the bubble counter. Open the bubble counter by a
quarter turn (bayonet) and fill with water to up the mark before closing again.