![JBL ES150PW Service Manual Download Page 3](http://html2.mh-extra.com/html/jbl/es150pw/es150pw_service-manual_3707433003.webp)
ES150PW
200W Powered Sub Amp
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-253
230
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Load Impedance (speaker)
4
Ohms
n/a
Nominal
AVG System impedance
5.18
Ohms
n/a
AP Computed BW from 20 to
500Hz
Min System impedance
3.769
Ohms
n/a
@ 100Hz
Rated Output Power (120VAC)
200
Watts
190
Domestic version only 120 VAC-60 Hz
AVG RMS Dynamic Power
311
Watts
Reference 200mV driven into LFE input
Average RMS power, 3/20 Cycles 50
Hz, Driven 6dB above its input
sensitivity , average of the RMS value
for the first 4 consecutive peaks
THD @ Rated Power
0.5
%
1
22K filter
THD @ 1 Watt
0.2
%
0.3
22K filter
DC Offset
10
mV-DC
30
@ Speaker Outputs
Damping factor
>50
DF
20
Measured at amplifier board 90%
of full power
Measured at the speaker cable. 180
Watts @ THD < 0.1 % @ 50 Hz
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
L or R
13
mVrms
±1dB
To 1 Watt
Single input driven
LFE input
7
mVrms
±1dB
To 1 Watt
Single input driven, LFE switch ON
System Gain (L or R inputs)
43.7
dB
Reference
Single input driven L or R inputs (Local
inputs)
System Gain (LFE input)
49.1
dB
Reference
Single input driven LFE Mode local
Signal to Noise
SNR-A-Weighted
80
dBA
75
relative to 1W
A-Weighting filter
SNR-unweighted
65
dBr
60
relative to 1W
22K filter
Residual Noise Floor
<1.5
mVrms(max)
2.5
Volume @max, w/ A/P Swept
Bandpass Measurement (Line
freq.+ harmonics) (BW=20 KHz)
Line level inputs must be terminated
using 1KOHM
Input Impedance
Line Input (L, R,LFE)
10K
ohms
n/a
Nominal
Filters
LP filter Variable (Normal mode)
50-150
Hz
± 10
4th Order variable-24 db/Octave
Subsonic filter (HPF) 2nd Order
Fixed
--
--
Friend circuit
Fixed
--
--
LFE Low pass
200>LP<500
Hz
LFE input driven only
Limiter
THD at Max. Output Power
5
%
Functional
Drive unit 6dB above the required
level to obtain full power
Approximately 800mV single input
driven, L or R input
Maximum THD as a result of limiting.
Features
--
Volume pot Taper (lin/log)
LOG
--
Functional
A Taper
Variable Crossover control
YES
--
Functional
Refer to Filter section
Phase switch
0-180
deg
Functional
LP Filter defeat switch
YES
Functional
Disables LP filter, Wireless mode only,
it has no effect when using local inputs
Wireless ready
YES
Functional
Refer to Wireless section below
Wireless channels
4
n/a
Functional
System is provided with 4 wireless
channels, which can be selected via a
rear panel switch, channel should
match ID at Tx side
LED Indicator
YES
Functional
RED-Standby, GRN-Active, ORG-
Wireless link and subwoofer are active.
Input Configuration
Line in (L,R) & LFE
YES
--
Functional
3 RCA Jacks, RED, WHT (Left and Right)
and Purple for LFE
ES150PW
2
Summary of Contents for ES150PW
Page 11: ...ES150PW 10...
Page 14: ...ES150PW 13...
Page 15: ...ES150PW 14...
Page 16: ...ES150PW 15...
Page 17: ...ES150PW 16...
Page 21: ...ES150PW 20...
Page 22: ...ES150PW 21...
Page 23: ...2 1 3 2 1 3 ES150PW 22...
Page 24: ...ES150PW 23...
Page 25: ...ES150PW 24...
Page 26: ...ES150PW 25...
Page 27: ...ES150PW 26...
Page 47: ...ES150PW 46...
Page 49: ...2 3 1 TL072 U105 A VEE U105 D VDD U105 C 6 5 7 U105 B TL072 ES150PW 48...
Page 50: ...Green Red D401 LED_5DIA ES150PW 49...
Page 51: ...ES150PW 50...
Page 52: ...ES150PW 51...
Page 53: ...ES150PW 52...
Page 54: ...ES150PW 53...
Page 56: ...L01 56R 2 1 ES150PW 55...
Page 59: ...ES150PW 58...