16
Maintenance and care
Build-up of dirt, limescale, etc. inside the casing prevents optimal functioning of the UV-C
Water Clarifier. Therefore, the inside of the appliance should be cleaned twice a year (or more
frequently if efficiency deteriorates noticeably). The UV-C bulbs should be replaced once a
year at the beginning of spring (for operation in garden ponds) or after max. 6-8000 hours of
operation.
For all maintenance work requiring the appliance to be opened, consult a qualified per-
son who is familiar with the hazards of unintentionally released UV-C radiation. (See
the separate instruction “for the specialist”)
Cleaning the covers of the bulb inspection windows
Before working on the appliance or in the aquarium/pond, all electrical appliances
must be disconnected from the mains/power supply. When doing so, never pull the
plug from the plug socket by the cable, and, instead, always hold the plug and then
pull it out.
Unscrew the covers of the inspection windows covers for checking fluorescent bulb function
(16) by turning counter-clockwise. Do not use any tools.
Clean the covers with water and a microfibre cloth (JBL WishWash). Do not use any aggres-
sive cleansing agents.
Check to make sure the O-rings (23) are intact and fit properly before screwing the covers on
again. Lubricate the O-rings with some Vaseline if necessary.
Cleaning the cover of the impeller inspection window and the impeller
Before working on the appliance or in the aquarium/pond, all electrical appliances
must be disconnected from the mains/power supply. When doing so, never pull the
plug from the plug socket by the cable, and, instead, always hold the plug and then
pull it out.
Unscrew the cover of the impeller inspection window (19) by turning counter-clockwise.
Do not use any tools. Pull the impeller with the ceramic axle and the rubber tails (24) out by
pulling up.
Clean the cover and the impeller with water and a microfibre cloth (JBL WishWash). Do not
use any aggressive cleansing agents.
Replace the impeller with the ceramic axle and the rubber bearing.
Check to make sure the O-rings (23) are intact and fit properly before screwing the cover on
again. Lubricate the O-rings with some Vaseline if necessary.
Summary of Contents for AquaCristal UV-C 110 W
Page 2: ...JBL 72W 110W 1 11 17 15 3 18 4 2 2 14...
Page 3: ...1 a b c...
Page 4: ...4x 2 3...
Page 5: ...5 6 4...
Page 6: ...JBL 72W 110W 1 2 3 4 9 10 19 23 11 5 24 12 5 7 8 13 14 15 16 23 17 18 21 22 20 8...
Page 106: ...100 4 16 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25...
Page 107: ...101 26 30 27 28 29 101 102 102 103 103 105 107 108 DE UK FR NL IT DK ES PT SE CZ PL RU...
Page 110: ...104 JBL AquaCristal UV C 4 2 1 1 10 11 12 13 14 JBL AquaCristal UV...
Page 112: ...106 16 JBL Wish Wash 23 19 24 JBL WishWash 23...
Page 113: ...107 DE UK FR NL IT DK ES PT SE CZ PL RU...
Page 117: ...JBL 72W 110W 1 11 17 15 3 18 4 2 2 14...
Page 118: ...1 c d 1 2 1 e f Klack a b 2 3 2 3 1...
Page 119: ...2 c 1 2 1 f a 2 3 2 3 b 1...
Page 120: ...3 c a b...
Page 121: ...JBL 72W 110W 1 2 3 4 9 10 19 23 11 5 24 12 5 7 8 13 14 15 16 23 17 18 21 22 20 8...
Page 151: ...30 4 8 20 21 JBL WishWash JBL Clean A 22 8 JBL GmbH Co KG Dieselstr 3 67141 Neuhofen Germany...