6

Clean periodically

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool.

- Use a damp cloth to clean the casing, the  
  stand and the tool. Alcohol can only be used  
  to clean the metal parts.

- Check periodically that the metal parts of  
  the tool/stand are clean so that the station  
  can check the tool status.

- Maintain tip surface clean and tinned prior to 

storage in order to avoid tip oxidation. Rusty 
and dirty surfaces reduce heat transfer to the 
solder joint.

- Periodically check all cables and tube    
 connections.

- Replace any defective or damaged parts.  
  Use original JBC spare parts only.

- Repairs should only be performed by a 
  JBC authorized technical service.

Summary of Contents for KNE

Page 1: ...KNE Nitrogen Regulator Kit for DDE DME and HDE Control Units INSTRUCTION MANUAL ...

Page 2: ...le 1 unit Ref T245 NA Stand 1 unit Ref DN SF Stand Cable 1 unit Ref 0024227 Sponge 1 u Ref CL6210 Nozzles 2 units Ref B7244 x1 B7968 x1 Cartridge 1 unit Ref C245903 Manual 1 unit Ref 0020524 Module Cable 1 unit Ref 0024228 Sponge 1 unit Ref S7034 This manual corresponds to the following reference KNE B ...

Page 3: ...Module GN Nitrogen Generator Module DDE DME HDE Control Unit Stand Cable Ref 0024227 Module Cable Ref 0024228 DNS Stand for Nitrogen Handles Nitrogen Handle Ref T245 NA T210 NA Sold separately T470 NA For HDE Station Sold separately Handle N2 tube Compressed Air Inlet or from N2 net N2 pressure range supply 3 to 6 bar 6 bar MAX Nitrogen supply tube Electric circuit www jbctools com ...

Page 4: ... Remember your first connection is denoted as a the second as b etc e g MNE_a MNE_b 3 Press Menu or Back to save changes Initial Set up When a new MNE is detected a pop up screen appears with instructions If no screen appears click on the icon on the main bar and follow the steps Once set up you can change the module settings by entering the Peripherals Menu For DDE and HDE Control Units For DME C...

Page 5: ...dering iron is lifted from the stand 2 The flow is interrupted when the tool is returned to the stand and the temperature drops for the tip to go into the Sleep mode Use the P 005 Pedal to enable disable the module This pedal will work with any module or tool regardless of the module to which it is connected Operation Accessories Recommended N2 flow 1 2 SLPM N2 flow control This light indicates wh...

Page 6: ...that the metal parts of the tool stand are clean so that the station can check the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tube connections Replace any defective or damaged parts Use original JBC spare parts only Repairs should only be perfo...

Page 7: ... grills Heat can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children...

Page 8: ...lid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase para manuales color gris 0031034 010323 KNE Nitrogen Regulator Kit for DDE DME HDE Control Units Ref KNE B Weight 3 7 kg 8 2 lb Dimensions MNE 55 x 130 x 140 mm 2 x 5 1 x 5 5 in Voltage AC 24V from c...

Reviews: