6
Guide Tube
Set
Outlet Nozzle Replacement
Flux can cause clogging at the outlet nozzle of the guide tube set and it can be necessary to replace
the worn or clogged outlet nozzle.
Note:
There is a nozzle size for each soldering wire diameter. The use of the nozzle is necessary as
its inner diameter is adjusted to the solder wire diameter and guides the wire with greater precision.
To replace the outlet nozzle, follow these steps:
First, make sure that the tool has cooled down and unload any remaining solder wire that might still
be inside the guide tube (see pages 11 and 12). Unplug the tool. Loosen the guide tube set screw (1)
and detach the guide tube set from the tool for easier handling.
Unscrew the spring inwards (2), following the downward direction of the spring.
AP250
AL250
AL250
SF280
SF250
ALE250
Once the outlet nozzle is released from the spring, pull the outlet nozzle out (3) and then remove the
spring (4).
Once the outlet nozzle is set in place, screw the spring onto it to fix the outlet nozzle onto the guide
tube (6).
Place the new outlet nozzle onto the guide tube set (5).
First, make sure that the tool has cooled down and unload any remaining solder wire that might still be
inside the guide tube (see page 7). Unplug the tool. Loosen the guide tube set screw (1) and detach
the guide tube set from the tool for easier handling.