Upper
centering jig
Lower
centering jig
6
Centering Jig
Instal both, lower and upper centering jigs, on
CSR and the soldering iron as shown.
Adjust the soldering iron position until the
centering jig is aligned. It must be possible to
move in and out smoothly.
Insert the centering jig completely. Set this
point as the pick-up point position. From
this point on, the soldering iron should do a
linear movement when inserting or removing
cartridges.
In order to align CSR to the soldering iron and set the cartridge pick-up points use JBC´s centering jig.