www.jbctools.com
10
11
Menu Screen
Main menu
Counters
Tool settings
4 Counters
5 Program version
4 Hibernation hours 0
5 No tool hours 0
6 Sleep cycles 0
4 Sleep temp 180
0
C
5 Hibernation delay
3
0 min
6 Temp adjust + o
o
C
Tool 245
Tool 245
Back
Back
Station settings
Back
Pre-set PIN: 0105
This screen displays
information of tool status
in real time.
0
c
Selected temp. 350
o
C
P o w e r 1 0 %
Fixed temp.
350
o
C
Shown when you fix a
specific temp.
Shown when you have
selected temp. levels.
Work Screen
Process Control
1
Fix one temp
-----
2 Temp levels set oFF
3
Sleep delay 0 min
5 Beep oN
6 Change PIN
1
Temp unit
Celsius
2
Maximum temp 400
0
C
3 Minimum temp 200
0
C
4 Help text oFF
Levels
º
C 270
350
400
1
Plugged hours
0
2 Working hours 0
3
Sleep hours 0
350
Exit
1
Reset settings
2 Station settings
3
Tool settings
Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
Remove the fuse by pulling the black cap.
If necessary use a tool to lever it off.
Press the new fuse into the holder and
replace it in the station.
Clean
periodically
- Use a damp cloth to clean the casing and
the tool. Alcohol can also be used to clean
the metal parts.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cable connections.
Maintenance
- Replace a blown fuse as follows:
- Replace any defective or damaged parts. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.