background image

www.jbctools.com

10

11

Menu Screen

Main menu

Counters

Tool settings

4      Counters
5       Program version

4   Hibernation hours          0 
5    No tool hours                     0
6    Sleep cycles                       0

4   Sleep temp                   180

0

5     Hibernation delay     

3

0   min

6   Temp adjust                + o  

o

C

Tool 245

Tool 245

Back

Back

Station settings

Back

Pre-set PIN: 0105

This screen displays 
information of tool status 
in real time.

0

c

Selected temp.  350 

o

C

P o w e r   1 0 %

Fixed temp. 

 350

 

o

C

Shown when you fix a 
specific temp. 

Shown when you have 
selected temp. levels.

Work Screen

Process Control

1      

Fix one temp    

            -----

2    Temp  levels  set          oFF

3

    Sleep delay                0   min

5    Beep                                     oN
6    Change PIN                      

1    

Temp unit    

            Celsius

2

    Maximum  temp      400

0

C

3    Minimum  temp          200

0

C

4    Help text                           oFF

Levels 

º

C  270  

350 

 400

1   

 Plugged hours    

             0

2   Working hours                0

3

   Sleep hours                       0

350

      

  

Exit

1       

 

Reset settings

2       Station settings

3

       Tool settings

Before carrying out maintenance or storage, always allow the equipment to cool. 

- Clean the station screen with a glass cleaner 

or  a damp cloth.

Remove the fuse by pulling the black cap.  
If necessary use a tool to lever it off.

Press the new fuse into the holder and 
replace it in the station.

Clean  
periodically

- Use a damp cloth to clean the casing and 

the tool. Alcohol can also be used to clean 
the metal parts.

- Periodically check that the metal parts of 

the tool and stand are clean so that the 
station can detect the tool status. 

- Maintain tip surface clean and tinned prior 

to storage in order to avoid tip oxidation. 
Rusty and dirty surfaces reduce heat 
transfer to the solder joint.

- Periodically check all cable connections.

Maintenance

    
- Replace a blown fuse as follows:

- Replace any defective or damaged parts. Use original JBC spare parts only. 

- Repairs should only be performed by a JBC authorized technical service.

Summary of Contents for CP-D

Page 1: ...www jbctools com Espa ol 15 English 3 Page Compact Micro Tweezers Station Ref CP D...

Page 2: ...included CP Control Unit 1 unit Ref CP 1D 120V CP 2D 230V CP 9D 100V Brass Wool 1 unit Ref CL6210 www jbctools com Sponge 1 unit Ref S0354 Micro Tweezers 1 unit Ref PA120 A Cartrdiges 2 units Ref C12...

Page 3: ...rocess Control Adjustable Stand Intelligent Heat Management Equipotential connection USB B connector Features Micro Tweezers Ref PA120 A Adjustable stand Cable collector Adjust the tool stand to suit...

Page 4: ...20 When used carefully it provides a more thorough cleaning Splashguard Tip Wipe Changing cartridge Compatible cartridges CP station works with C120 cartridge range Check the model that best adapts to...

Page 5: ...ager Settings Change settings for a group of JBC stations at the same time any JBC station USB Hub Cable USB AB Operation The JBC Exclusive Heating System Our revolutionary technology is able to recov...

Page 6: ...eset settings 2 Station settings 3 Tool settings Before carrying out maintenance or storage always allow the equipment to cool Clean the station screen with a glass cleaner or a damp cloth Remove the...

Page 7: ...d when not in use in order to activate the sleep mode Thesolderingtip themetalpartofthetoolandthestandmaystillbehotevenwhenthestationis turned off Handle with care including when adjusting the stand p...

Page 8: ...CP 1 unidad Ref CP 1D 120V CP 2D 230V CP 9D 100V Brass Wool Lana de lat n 1 unidad Ref CL6210 www jbctools com Sponge Esponja 1 unidad Ref S0354 Micro Tweezers Micro pinzas 1 unidad Ref PA120 A Cartrd...

Page 9: ...icro pinzas Ref PA120 A Soporte Ajustable Recogecable Ajuste el soporte de la herramienta para adaptarlo a su posici n de trabajo Coloque el cable en el recogedor y ajuste su posici n para evitar mole...

Page 10: ...guard not supplied Inox Wool Lana inoxidable Ref CL6205 Un m todo alternativo a la lana de lat n Metal Brush Cepillos de metal Ref CL6220 Si se utiliza con prudencia proporciona una limpieza m s profu...

Page 11: ...tings Menu Configure la temperatura de Sleep Retrase la entrada al modo Sleep de 0 a 9 min o no Sleep Tool Settings Menu Retrase la entrada al modo Hibernation de 0 a 35 min o no Hibernation Funcionam...

Page 12: ...350 Exit 1 Reset settings 2 Station settings 3 Tool settings Antes de almacenar o de su mantenimiento el equipo debe estar desconectado de la fuente de alimentaci n y dejar que se enfr e Use un pa o...

Page 13: ...e cuando no est en uso con el fin de activar el modo de Sleep El cartucho la parte met lica de la herramienta y el soporte puede estar caliente incluso cuando la estaci n est apagada Maneje con cuidad...

Page 14: ...www jbctools com 26 27 Exploded View Despiece...

Page 15: ...ta garant a de 2 a os cubre este equipo contra cualquier defecto de fabricaci n incluyendo la sustituci n de partes defectuosas y mano de obra La garant a no cubre el desgaste del producto por uso o m...

Reviews: