![jbc CP-1E Manual Download Page 6](http://html.mh-extra.com/html/jbc/cp-1e/cp-1e_manual_637026006.webp)
ø0,7
1,5mm
ø 0,2
5mm
6mm
C120-009
C120-010
2. Inserting
3. Aligning
4. Fixing
Align the tip of the cartridge.
Use a flat pliers for a correct tip alignment.
Do not over-tighten the cartridge.
Changing cartridge
To change a cartidge safely, unplug the tool or turn the station off before following these guidelines:
Loosen the screw and remove the cartridge.
Use a flat pliers if still hot.
1. Removing
Important:
Tighten the screw again being
careful not to over-tighten. This is necessary
for the tool to function.
Important:
Insert the cartridge as far as the
mark for a correct connection.
Mark
Alignment
Compatible cartridges
The
CP station
works with
C120
cartridge range.
Find the model that best suits your soldering needs in
www.jbctools.com
C120-004
C120-001
C120-005
C120-009 C120-010