Hibernation Delay
Set the time the tool will re-
main at Sleep temperature be-
fore entering the Hibernation
mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
This function completely
protects the tip from oxida-
tion during long periods of
inactivity while the tool is in
the stand.
Retinning the tip before pla-
cing the tool in the stand also
helps prevent oxidation and
extends the life of the tip.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends the
use of TID-A or TIA-A Ther-
mometers to obtain precise
readings.
Tool Settings
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartrid-
ge. E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
Recommendations
Parameter description
Warnings
12