00
13
84
0-
02
14
TECHNICAL SPECIFICATIONS
- Temperature selection from 90°C (190°F) to 450°C (840°F) (±5%).
- Output Peak Power CD-BC: 130W.
- Safety transformer, mains separator and double isolation.
-
CD-1BC
120V 50/60Hz. Input fuse: 2A. Output: 23,5V. Control Unit model:
CD-1C
-
CD-2BC
230V 50/60Hz. Input fuse: 1A. Output: 23,5V. Control Unit model:
CD-2C
-
CD-9BC
100V 50/60Hz. Input fuse: 2A. Output: 23,5V. Control Unit model:
CD-9C
- Total unit weight: 2,6 Kg. (5.7lb)
- Complies with CE standards according to the following directives:
2006/95/CE, 2004/108/CE, 2011/65/EU
- ESD protected housing “skin effect”.
- Equipotential connector and the tool tip are connected to the station’s mains grounding
for ESD protection.
This product should not be thrown in the garbage.
In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life
must be collected and returned to an authorized recycling facility.
WARRANTY
JBC’s 2 year warranty covers this equipment against all
manufacturing defects, including the replacement of defective
parts and labour.
Warranty does not cover product wear due to use or mis-use
and shall be void if the equipment has been tampered with by
unauthorised persons.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing
this form duly filled in.
www.jbctools.com
SERIAL Nº
DEALER’S STAMP
DATE OF PURCHASE
Visit our website to see the updated manuals.