![jbc B-IRON 210 DUAL Instruction Manual Download Page 13](http://html2.mh-extra.com/html/jbc/b-iron-210-dual/b-iron-210-dual_instruction-manual_4824058013.webp)
Tool
ON
MENU
28174
24 W 100%
18 W 100%
12 W 100%
6 W 100%
0 W 100%
10 seconds/div
V1.2
CHARGE
450 ºC
350 ºC
250 ºC
150 ºC
50 ºC
JBC
210
348ºC
5,7 W
80%
350ºC
Tool
ON
MENU
24 W 100%
18 W 100%
12 W 100%
6 W 100%
0 W 100%
10 seconds/div
V1.2
WORK
450 ºC
350 ºC
250 ºC
150 ºC
50 ºC
80%
JBC
210
350ºC
Tool
ON
MENU
24 W 100%
18 W 100%
12 W 100%
6 W 100%
0 W 100%
10 seconds/div
V1.2
CHARGE
450 ºC
350 ºC
250 ºC
150 ºC
50 ºC
JBC
210
348ºC
5,7 W
80%
350ºC
JBC#1
JBC#1
MENU
Tool1
2822
Tool ID
Hibernation delay
Temperature units
00:30
Maximum Temperature
400ºC
Sleep mode
Sleep temperature
150ºC
Working
Low battery
Power OFF
Charging
No cartridge
Tool Status
ºC
ºF
JBC
210
Lock Parameters
Locked
Unlocked
Return to Work
Tool1
Tool ID
28714
Hardware
Software
0028283
X886787
Update File
File
Hardware
Software
Select your Firmware
-
-
Update
MENU
JBC
210
Return to Work
JBC#1
Bi115
Bi210
User’s Manual
User’s Manual
Documents
MENU
JBC#1
JBC
210
Return to Work
2822
Work
Settings
Counters
Update
Documents
Light Theme
Dark Theme
Disconnect
JBC#1
Update
Tool
ON
MENU
JBC#1
24 W 100%
18 W 100%
12 W 100%
6 W 100%
0 W 100%
10 seconds/div
V1.2
WORK
450 ºC
350 ºC
250 ºC
150 ºC
50 ºC
80%
JBC
210
350ºC
Tool1
Tool1
Tool1
Tool1
Tool2
Tool3
Tool
ON
MENU
24 W
18 W
12 W
6 W
0 W
10 seconds/div
V1.2
CHARGE
450 ºC
350 ºC
250 ºC
150 ºC
50 ºC
JBC
210
80%
350ºC
JBC#1
348ºC
6 W
10
10
Stopping Data Display
When the tool is placed on the tool holder or when it enters Hibernation Mode, the data display stops.
The display starts again automatically when the tool is lifted from the tool holder and the graph is
automatically displayed again at the point where the previous display stopped, leaving a small gap on
the graph between the last registered value and the new starting point.
Working with Two Tools
When working with two tools, to switch between the two graphs, tap on the tool selector (upper-right
corner of the display) and select the desired tool from the drop-down menu.
It is also possible to alternate both graphs by simply lifting one tool or the other from the tool holder.
The display will automatically show the graph and information of the tool in use.
Note:
All menu items are explained in detail starting at section “Menu”.
Work Screen
Connected Tool and Tool
Selector
When the tool is not in use
the graph stops recording
1
2
Retention
Clamps
Cartridge Exchanger
Cartridges are held in place inside the cartridge
exchanger thanks to the retention clamps, with
the advantage that the cartridges do not fall
into the exchanger and the cartridge tips are
therefore protected. The cartridge exchanger
of B·IRON stations works with C210 and C115
cartridges.
Cartridge Retention
The cartridge exchanger saves time and allows to change cartridges safely without switching the
tool off.
Place the cartridge over one of the slots of the
cartridge exchanger and press down (1) until
you hear a click. Then pull the handle out (2)
to remove the cartridge.
1. Removing Cartridges
Cartridge
Exchanger
C115
Cartridge
Place the handle over a cartridge and press the
handle down to insert the cartridge.
2. Inserting Cartridges
C115 Cartridge Retention Area
The holding area of C115 cartridges is delimited
by the two rings before the tip.
C210 Cartridge Retention Area
The holding area of C210 cartridges goes from
the start of the tip until the cartridge begins
to widen.
C210
Cartridge
13
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm