Safety

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.

- The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire.

- Do not work on electrically live parts.

- The tool should be placed in the stand when not in use in order to charge the batteries. 

- The soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the 

station is turned off. 

- Do not leave the appliance unattended when it is on.

- Avoid flux coming into contact with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working 

to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

- This appliance can be used by children over the age of eight and also persons with reduced physical, 

sensory or mental capabilities or lack of experience provided that they have been given adequate 
supervision or instruction concerning use of the appliance and understand the hazards involved. 
Children must not play with the appliance.

- Maintenance must not be carried out by children unless supervised.

- Do not expose the console to high temperatures, humidity or dust. Avoid direct sunlight. 

- Do not drop the console as it may cause damage or malfunction.

- Do not disconnect your device when it is in file transfer mode.

- Do not use the console in places were electronic devices are resticted.

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

14

Summary of Contents for B iRON 115

Page 1: ...Nano B iRON Station B iRON 115 INSTRUCTION MANUAL ...

Page 2: ...CL0300 already assembled in the stand B 115 Nano Tool 1 unit Ref B115 A This manual corresponds to the following references Console included BI115UA 120 V N America Taiwan BI115IA 230 V India BI115A 230 V Europe BI115KA 230 V United Kingdom BI115HA 230 V China BI115JA 100 V Japan Cable USB 1 unit Ref 0028092 B iRON Console 1 unit included according purchased reference Console not included BI115UQA...

Page 3: ...ce like PC or mobile can be connected Power Socket USB Connector USB Cable only for charging Bluetooth Connection Stand for B 115 Nano Tool Screw to detach the Support Quick Tip Changer Brass Wool inside Cartridge Storage Antisplash Membrane Cartridge C115 Range not included 3 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 4: ...stand 2 Note Charge the tool completely 30 min before using for the first time The status indicator light idicates as follows the tool status Green Working Soldering Green blinking Charging Red Low Battery Red blinking No Cartridge No color Power OFF 2 1 Status Indicator Light 1 Connection 2 Cartridge Insertion and Charging 4 ...

Page 5: ...C Selected temperature 100 100 75 100 50 100 25 100 0 100 450ºC 350ºC 250ºC 150ºC 50ºC 10s div Temp Power 115 3 Switching on Console Device Select the tool from the detection list Turn on the console device and open the B iRON Application 4 Selecting Tool Console Work Screen Temperature and Power Grafics Application Menu Connected Tool Lock Default PIN 0105 Temperature Selection Detection List Too...

Page 6: ...e When the tool is in the stand enters into Hibernation Mode and cools down to room temperature While the tool remains in the stand it charges Hibernation When the tool is outside of the stand and remains inactive no movement the tool enters into Hibernation mode and cools down to room temperature To turn the tool on put it back into the stand Note When the tool is lifted from stand the Soldering ...

Page 7: ...apping or wiping the cartridge tip If the tip is very dirty JBC recommends first cleaning it with the wiper to remove excess solder and than with the brass wool Brass Wool Ref CL0300 Very effective cleaning method Leaves a small layer of solder on the tip preventing oxidation between cleaning and rewetting Tap gently to remove excess solder Use the slots to remove remaining particles Wiper Tapping...

Page 8: ... that the brass wool is on the far left and that there is space for the wiper on the right Assemble the antisplash membrane in vertical direction onto the stand Press the antisplash membrane down Make sure that the membrane is correctly inserted all around Note The brass wool and the wiper position can be reversed by rotating the antisplash membrane 180 degrees 8 ...

Page 9: ...nd press down slightly Important Insert the cartridge until the metal ring comes to a stop The charging indicator light changes from red to green when the cartridge is proprely inserted Conical Chisel Conical Bent Bevel Compatible Cartridges B 115 Pecision Tool works with C115 Cartridges Find the model that best suits your soldering needs in www jbctools com until stop 9 40 mm 50 mm 60 mm 80 mm 10...

Page 10: ...ing the Grips For Precision Tool Ref B210 A and for Nano Tool Ref B115 A soft foam grips Ref 0026437 are available Remove the prior grip and replace the grips easily using the slip on tabs To change the grips do as follows 1 Inserting Tabs 2 Inserting Handle 3 Removing Tabs Menu Settings The B iRON Console offers an intuitive user interface which provides quick access to station parameters Origina...

Page 11: ... delay from 5 to 60 sec Countdown starts when no movement ist detected Set shutdown delay from 1 to 10 min Countdown starts when no movement ist detected Set sleep mode ON OFF The tip temperature will drop to the selected sleep temperature Choose between 2 different modes to show tool status The tool status light indicates as follows the tool status Green working soldering Green blinking charging ...

Page 12: ...ery 80 350ºC Selected temperature 100 100 75 100 50 100 25 100 0 100 450ºC 350ºC 250ºC 150ºC 50ºC 10s div Temp Power 115 115 Download the JBC update file from https www jbctools com jbcsoftware html Connect the console device via USB connection to the PC Ontheconsole devicenotificationbaratthetop open USBConnectionSettings andselect MTP On the PC copy the downloaded file to IT706 internal share st...

Page 13: ...he tool and stand are clean so that the charging works properly Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Do not use liquid such as alcohol thinner or benzene to clean the console Repairs should only be performed by a JBC authorized technical service Maintenance Clean periodically 13 40 m...

Page 14: ...nd gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards i...

Page 15: ...tery Li Ion 7 4 V 3 A Charge Time 40 minutes Temperature Range 200 450 C 390 840 F Idle Temp Stability still air 1 5 C 3 F Temp Accuracy 3 Using reference cartridge Connections Bluetooth Low Energy BLE Ambient Operating Temp 10 50 C 50 122 F Total Net Weight 1 34 kg 2 95 lb Total Package Dimensions Weight 265 x 223 x 160 mm 1 90 kg L x W x H 10 43 x 8 78 x 6 30 in 4 18 lb Complies with CE standard...

Page 16: ...rranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase...

Reviews: