15
MP 2260 PICK & PLACE PEN
The
MP 2260
pick & place pen ref. 2260000 for
the placing of SMD is also delivered with the
AM 6500
.
The pen is connected to the plug VACUUM of the
station. Please find the connection plan on page 1.
A set of straight and bent needles as well as a
set of different sized suction cups is delivered
with the station:
- Set of suction cups
Ref. 0940163
- Set of straight needles
Ref. 0901546
- Set of bent needles
Ref. 0861660
The suction cups can be adjusted to the
needles in order to make the placement of SMD
of different sizes on boards easier.
These accessories allows the adjustment to
weight and size of any type of component.
Component pick-up (Fig. A)
Place the needle tip on the component and block
the control orifice with the first finger of the other
hand so that the component may be held to the
needle by suction
.
Component placing (Fig. B)
Place the component in position on the printed
circuit. Remove your finger from the orifice
allowing air to enter whereby the component will
be released in the desired position
.
Faults and remedies
We list below the most frequent faults and the
possible remedies which you yourself may be
able to apply. In any case, the JBC technical
assistance service will attend to you if required.
Insufficient suction
The tubes have to be checked for possible air
escapes and the correct connection of the tubes
to their terminals must be observed. Check the
incoming air filter in the interior of the station
and replace it if dirty or obstructed.
If in spite of this the suction is insufficient, the
s e l f - c o n t a i n e d v a c u u m p u m p s h o u l d b e
checked.
Filter
Ref. 0861800
When you assemble the suction cup with the
needle, you should avoid the needle to stick out
of the lower part.
Fig. A
Fig. B
CUPS
Ref.: 0940163
STRAIGHT
NEEDLES
Ref.: 0901546
Ø
A
mm
COLOR
2 x 4,3
BLACK
YELLOW
2 x 7
PINK
2 x 10
Ø
B
mm
2 x 0,7
2 x 0,9
2 x 1,2
BENT
NEEDLES
Ref.: 0861660
COLOR
GREEN
YELLOW
PINK
Ø
B
mm
2 x 0,8
2 x 0,9
2 x 1,2