ENGLISH
2
JBC reserves the right to make technical changes without
prior notification.
Changing the cartridge
To extract the cartridge the screw needs to
be unfastened and the cartridge pulled out.
I n s e r t t h e n e w c a r t r i d g e a n d p u s h i t
thoroughly. Then check that both tips of the
tweezers coincide and screw it.
Important.
-
It is essential to insert the cartridge till the
end for a good connection. Take the mark
as reference and check that both parts
of the tweezer coincide.
Alignment
Cartridge and electric
connection screw
Ref. 0780841
Ref. 0741610
A
A
A
ØA
A
Ref.
A mm
2245-271
1,5
2245-272
2,5
Chip components
Ref.
A mm
2245-273
4,0
2245-274
6,0
2245-275
8,0
2245-276 10,0
2245-277 15,0
2245-278 20,0
Dual in line IC
Ref.
A mm
2245-279
8,0
2245-280 11,0
QFP and PLCC
Ref.
A mm
2245-281
2245-282
Cable stripper
RANGE OF CARTRIDGES
PA 4200
has an individual temperature
control for each cartridge so it is supplied
individually.
2245-281
2245-282
3,5 max
Ref.
A mm
2245-283
50
Blade type
WARNING: It is esential to tighten this screw
for the tool to function.