WORLD STAR/COLOR BALL

LAMP (RE)PLACEMENT

In case of replacement of the lamp or maintenance,
do not open the fixture within 15 minutes until the
unit cools down after switching off. Always unplug
the unit before servicing! Always use the same type
of spare parts (bulbs, fuses, etc.) When replacing

parts, please only genuine spare parts.

Unplug the mains cable to switch off the unit

Wait for about 15 minutes until the unit has been cooled down.

Use a screwdriver to unscrew the 3 screws of the dome.

( A on

the drawing )

On the inside of the dome you will see the lamp socket

Unplug the old lamp. Hold the lamp socket while unplugging the lamp

Hold the lamp socket while pressing the new lamp gently in the
socket.

Attention!

Check the label on the backside of the device or see the

technical specifications in this manual to know which lamp should be used. Never install lamps with a higher wattage!
Lamps with higher wattage generate temperatures the device was not designed for. If the device uses a lamp
transformer, it will burn due to current overload.

Don’t touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you touched the lamp, clean
it with a cloth and a little denatured alcohol. Wipe the lamp off before installing.

Close the dome with the 3 screws.

Done!

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper installation can
result in serious injuries and/or damage to property.

Overhead rigging requires extensive experience!

Working load limits should be respected, certified installation materials should be used, the installed device
should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be
fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. This
secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if
the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by an expert
before using them for the first time. The installations should be inspected every year by a skilled person to be sure that
safety is still optimal.

OPERATING INSTRUCTIONS

Once connected to the mains the device starts running.

Regular breaks during operation are essential to maximize the life of this device as it is not designed for continual use.

Do not switch the unit on and off in short time intervals as this reduces the lamp life.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare-hands during its operation.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons suffering from

epilepsy.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/24

WORLD STAR/COLOR BALL

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light
output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly
dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:

AC 230V, 50Hz

Fuse:

5A/250V

Lamp:

EHJ 250W 24V lamp

Size:

35 x 35 x 40cm

Weight:

6 kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Summary of Contents for World star Color ball

Page 1: ...cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de i...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...ratures when bringing it into a warm room after transport Condense sometimes prevents the unit from working at full performance or may even causedamages This unit is for indoor use only CAUTION ENGLIS...

Page 4: ...eating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected e...

Page 5: ...condensation emp che l unit de fonctionner en performance optimale et peut m mecauser des dommages FRAN AIS MODE D EMPLOI JB SYSTEMS 6 24 WORLD STAR COLOR BALL Cette unit est destin e une utilisation...

Page 6: ...x et ne devrait pas tre consid r Ne pas couvrir les ouvertures de ventilation pour viter tout risque de surchauffe L utilisateur doit s assurer que les installations techniques et de s curit sont bien...

Page 7: ...laat het apparaat aan de omgevingstemperatuur wennen wanneer het na het transport naar een warm vertrek is overgebracht Condensatie kan het toestel soms verhinderen perfect te functioneren Het kan som...

Page 8: ...ker moet er zich van verzekeren dat de installaties met betrekking tot de veiligheid en de technische mechaniek door een expert zijn goedgekeurd alvorens ze voor de eerste keer te gebruiken Elk jaar m...

Page 9: ...inigen Minuten Zur Vermeidung von Stromschlag oder Feuer Ger t bitte nicht Regen oder Feuchtigkeit aussetzen Zur Vermeidung von Kondensation im Inneren des Ger ts bitte nach Transport in eine warme Um...

Page 10: ...herstellen dass die sicherheitsrelevanten und technischen Installationen vor Erstbetrieb fachm nnisch vorgenommen worden sind Installationen sollten j hrlich durch qualifiziertes Fachpersonal inspizie...

Page 11: ...a unidad se adapte a las temperaturas circundantes cuando la lleve a una habitaci n c lida despu s de transporte Condensaci n algunas veces impide que la unidad funcione a rendimiento pleno o puede in...

Page 12: ...asegurarse de que las instalaciones relativas a seguridad maquinaria y t cnica est n aprobadas por un experto antes de usarlas la primera vez Las instalaciones deber an ser inspeccionadas cada a o por...

Page 13: ...os N o introduza objectos de metal nem verta l quidos no interior do produto correr risco de choque el ctrico ou poder danificar o produto Caso algum objecto estranho entre em contacto com o interior...

Page 14: ...stala o aprovada em termos de seguran a e em termos t cnicos por uma pessoa qualificada antes de efectuar a primeira utiliza o A instala o dever ser inspeccionada todos os anos por um t cnico qualific...

Reviews: