JB Systems PIXEL PIPE Operation Manual Download Page 4

ENGLISH 

USER MANUAL 

 

 
JB SYSTEMS

®

 

2/11 

PIXEL PIPE

 

SAFETY INSTRUCTIONS: 

 

  To protect the environment, please try to recycle the packing material as much as possible. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

  D

on’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign 

object enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture 

must be fixed at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

 

Maximum safe ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures. 

  Make  sure  the  area  below  the  installation  place  is  free  from  unwanted  persons  during  rigging, de-rigging 

and servicing. 

  Allow the device about 10 minutes to cool down before to start servicing. 

  Always unplug the unit when it is not used for a longer time or before to start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the unit. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged. It must be replaced  by the  manufacturer, its service agent or similarly  qualified 
persons in order to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed in order to comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In order to prevent electric shock, do not open the cover. There are no user serviceable parts inside. 

 

Never

 repair a fuse or bypass the fuse holder. 

Always

 replace a damaged fuse  with a fuse of the same 

type and electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

 

CAUTION:

  To  reduce  the  risk  of  electric  shock,  do  not  remove 

the  top  cover.  No  user-serviceable  parts  inside.  Refer  servicing 
to qualified service personnel only. 

 

The lightning flash  with arrowhead symbol  within the  equilateral triangle  is intended to alert  the 
use or the presence of un-

insulated “dangerous voltage” within the product’s enclosure that may 

be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of  important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This  symbol  determines:  the  minimum  distance  from  lighted  objects.  The  minimum  distance 
between light-output and the illuminated surface must be more than x meters 

 

The device is not suitable for direct mounting on normally flammable surfaces. (suitable only for 
mounting on non-combustible surfaces) 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

Summary of Contents for PIXEL PIPE

Page 1: ......

Page 2: ......

Page 3: ...ion and individual RGB control Low power consumption only 12W For indoor use only 0 100 dimming and strobe function 4digit LED display for easy menu navigation Tripod stand BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device left our factory in perfect condition an...

Page 4: ...tely off when the power cord is squashed or damaged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when...

Page 5: ...ty Overhead rigging requires extensive experience Working load limits should be respected certified installation materials should be used the installed device should be inspected regularly for safety Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing The device should be installed out of reach of people and outside areas where pers...

Page 6: ... cable The unit starts working immediately in the last selected mode Refer to chapter HOW TO SETUP to learn how to switch between the different working modes Electrical installation for two or more units in master slave Connect several units together using good quality balanced microphone cables The unit that has no cable connected to its DMX input is the master the others are the slave units Make...

Page 7: ... the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Make sure that all units are connected to the mains Each light effect in the chain needs to have its proper start address so it knows which commands from the controller it has to decode In the section HOW TO SETUP you will learn how to set the DMX...

Page 8: ...se this function to put the fixture in fixed RED color Use the or buttons for dimming between 0 000 and 100 255 G000 G255 Green Use this function to put the fixture in fixed GREEN color Use the or buttons for dimming between 0 000 and 100 255 b000 b255 Blue Use this function to put the fixture in fixed BLUE color Use the or buttons for dimming between 0 000 and 100 255 FS00 FS15 Strobe Use this fu...

Page 9: ... disabled Stnd rev This function is used to inverse the display Use the or buttons to select the desired mode Stnd normal display rev inversed display dEFA This function is used to reset the fixture to its default factory settings Select dEFA the display is blinking Press the or buttons at the same time to reset the fixture to the default factory settings OPERATING INSTRUCTIONS A Standalone 1unit ...

Page 10: ...Press the B button then use the buttons 6 to adjust the blue component in the custom color 6 Buttons used to increase decrease the value of the selected function 7 Number buttons 0 9 used to set the DMX address 8 SPEED button SP used to change the running speed of the build in programs 9 SELECT PROG button PROG used to select one of the effect program modes With each press you go to the next effec...

Page 11: ... slow fast 6 000 051 No function 052 102 Static colors CH7 103 255 Programs CH7 7 000 031 CH6 052 102 No function 032 063 Red 064 095 Green 096 127 Blue 128 159 Yellow 160 191 Magenta 192 223 Cyan 224 255 White 7 000 011 CH6 103 255 Program 1 012 023 Program 2 024 035 Program 3 036 047 Program 4 048 059 Program 5 060 071 Program 6 072 083 Program 7 084 095 Program 8 096 107 Program 9 108 119 Progr...

Page 12: ...0 255 Blue1 0 100 4 000 255 Red2 0 100 5 000 255 Green2 0 100 6 000 255 Blue2 0 100 7 000 255 Red3 0 100 8 000 255 Green3 0 100 9 000 255 Blue3 0 100 10 000 255 Red4 0 100 11 000 255 Green4 0 100 12 000 255 Blue4 0 100 13 000 255 Red5 0 100 14 000 255 Green5 0 100 15 000 255 Blue5 0 100 16 000 255 Red6 0 100 17 000 255 Green6 0 100 18 000 255 Blue6 0 100 19 000 255 Red7 0 100 20 000 255 Green7 0 1...

Page 13: ...d or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Attention We strongly recommend internal cleaning to be...

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: