JB Systems PARTY SPOT Operation Manuals Download Page 5

ENGLISH 

USER MANUAL 

 

 
JB SYSTEMS

®

 

3/7 

PARTY SPOT 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 

 
DESCRIPTION: 

 

1.  DMX  INPUT: 

3pin  male  XLR-connector  used  to  connect  the 

projector  with  the  DMX  controller  or  with  the  previous  unit  in  the 
DMX chain.

 

2.  DMX  OUTPUT:

  3pin  female  XLR-connector  used  to  connect  the 

projector with the next unit in the DMX chain.

 

3.  Mains input:

 with IEC socket and integrated fuse holder, connect 

the supplied mains cable here.. 

4.  Mains  output 

with  IEC  socket:  you  can  use  a  special 

Male/Female  IEC  power  cable  to  connect  this  output  with  the 
mains  input  of  the  next  Party  Spot  for  easier  linking  up  to  10A. 
you  can  also  use  our  [JB  Systems  Combi  Cable]  to  link  power 
and dmx signal with one cable. 

5.  DISPLAY

 shows the various menus and the selected functions. 

6.  MODE button: 

used to browse the different functions in the menu 

7.  UP button:

 to increase the values shown on the display. 

8.  DOWN button: 

to lower the values shown on the display. 

9.  ENTER button: 

used to confirm your choice or to enter the setup 

mode of a function. 

 

OVERHEAD RIGGING 

 

Important:

 

The  installation  must  be  carried  out  by  qualified  service  personal  only.  Improper 

installation  can  result  in  serious  injuries  and/or  damage  to  property.    Overhead  rigging  requires 
extensive  experience!  Working  load  limits  should  be  respected,  certified  installation  materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below  the installation place  is free from unwanted persons  during rigging, de-rigging 

and servicing.  

  The device should be installed out of reach of people and outside areas where persons may walk by or be 

seated. 

  Before rigging make sure that the installation area can hold a minimum point load of 10times the devic

e’s 

weight. 

  Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. 

This  secondary  safety  attachment  should  be  installed  in  a  way  that  no  part  of  the  installation  can  drop 
more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

 

Don’t cover any ventilation openings as this may result in overheating.  

  The operator has to make sure that the safety-relating and machine-technical installations are approved by 

an expert before using them for the first time. The installations should be inspected every year by a skilled 
person to be sure that safety is still optimal. 

 

Summary of Contents for PARTY SPOT

Page 1: ......

Page 2: ......

Page 3: ...ny damage caused by mishandling is not subject to warranty The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual Keep this booklet in a safe place for future consultation If you sell the fixture be sure to add this user manual Check the contents Check that the packing contains the following items Operating instructions PARTY SPOT un...

Page 4: ...quashed or damaged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to ...

Page 5: ...browse the different functions in the menu 7 UP button to increase the values shown on the display 8 DOWN button to lower the values shown on the display 9 ENTER button used to confirm your choice or to enter the setup mode of a function OVERHEAD RIGGING Important The installation must be carried out by qualified service personal only Improper installation can result in serious injuries and or dam...

Page 6: ... for two or more units in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units with a good quality balanced cable To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this si...

Page 7: ...OMATIC SOUND MODE SoUn Used to select the automatic Sound Mode so colors will change automatically to the sound of the music Press the MENU button until SoUn is shown on the display Press the ENTER button to confirm DISPLAY ON OFF Used to select if the display should go out when not in use or if it should be always lit Press the MENU button until on or oFF is shown on the display Use the DOWN and ...

Page 8: ... projector in DMX mode select A A followed by 3 numbers and select the DMX address you need If no DMX signal is received the display will blink Since each unit has its own DMX address you can control them individually Remember that each unit uses 4 6 or 8 DMX channels depending on the DMX mode you have selected in the menu See the different DMX charts below DMX Chart for the 4 channel DMX Mode Sim...

Page 9: ...ng fans if any and ventilation openings should be cleaned monthly The interior of the device should be cleaned annually using a vacuum cleaner or air jet The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: