background image

ENGLISH 

 

USER MANUAL 

 

 
JB SYSTEMS® 

4/6 

MINI-PAR 12TC 

 

  Press the [ENTER] button 

 

  Now use the [UP] or [DOWN] to select the desired pulse speed. (01=slowest, 32=fastest)

 

 

3) STATIC COLOR MODES A1. & RGBW. 

 

You can set a static color in 2 Different ways: 

 
PRESET COLOR A1. 

  Press the

 

[MENU] button until the display shows [A1.00] (A1. Followed by 2 numbers) 

  Now use the [UP] or [DOWN] to select the desired color

 

 

MANUAL CUSTOM COLOR. 

If you need a color that is not available in the presets, you can compose your own color by adapting the 
intensity of each individual color (Red, Green, Blue) 

  Press the

 

[MENU] button until the display shows [rxxx] (r Followed by 3 numbers) 

  Now use the [UP] or [DOWN] to set the intensity of the Red color

 

  Press the

 

[MENU] button until the display shows [Gxxx] (G Followed by 3 numbers) 

  Now use the [UP] or [DOWN] to set the intensity of the Green color

 

  Press the

 

[MENU] button until the display shows [bxxx] (b Followed by 3 numbers) 

  Now use the [UP] or [DOWN] to set the intensity of the blue color

 

 

4)

 

MASTER /

 

SLAVE MODE: 

Several units can  be connected together to create nice synchronized shows.  The (slave) units will follow 
the instructions given by the first unit (master) in the chain.  
NOTE: it is important to execute the next steps in the correct order 

  Set the DMX address of all the slave units to [d001] before to connect them to the master unit . 

  Connect the DMX output of the master unit to the infput of the first Slave unit. 

  Connect the DMX output of the first Slave unit to the infput of the second Slave unit. 

  Etc. 

  Select the desired working mode in your master unit (fixed color, color fade, color change, etc

…) 

  All the connected slave devices will follow the program of the master unit. 

You can connect up to 32 units together. 

 

 

 