JB Systems INTRUDER Operation Manual Download Page 10

ENGLISH 

USER MANUAL 

 

JB SYSTEMS

®

 

8/11 

INTRUDER 

 

ELECTRICAL INSTAL ADDRESSING

 

Important:  The  electrical  installation  should  be  carried  out  by  qualified  personal  only, 
according to the regulations for electrical and mechanical safety in your country. 

 

Electrical installation for 1 standalone unit: 

 

Just insert the mains cable. The unit starts working immediately in stand-alone mode. 

 

Electrical installation for two or more units in master/slave: 

In this mode the units will show a synchronized show, working to the rhythm of the beat. 

 

 

 

 

Connect  2  to  maximum  16  units  together  using  good  quality  balanced  microphone  cables.  Put the  first 
unit in the chain in master mode (see Setup menu) and the other units as slaves (see Setup menu). 

 

Make sure that all units are connected to the mains.  

 

Done! 

 

Electrical installation in DMX-mode: 

 

The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to 
“daisy chain” your DMX controller and all the connected units with a good quality balanced cable. 

 

Both  XLR-3pin  and  XLR-5pin  connectors  are  used,  however  XLR-3pin  is  more  popular  because  these 
cables are compatible with balanced audio cables. 

Pin layout XLR-3pin: 

Pin1 = GND  ~  Pin2 = Negative signal (-)  ~  Pin3 = Positive signal (+)  

 

To  prevent  strange  behavior  of  the  light  effects,  due  to  interferences,  you  must  use  a  90Ω  to  120Ω 
terminator  at  the  end  of  the  chain.  Never  use  Y-

splitter  cables,  this  simply  won’t 

work!  

 

Make sure that all units are connected to the mains.  

 

Each light effect in the chain needs to have its proper starting address so it knows 
which commands from the controller it has to decode. In the next section you will 
learn how to set the DMX addresses. 

 

 

 

HOW TO SET THE RIGHT STARTING ADDRESS: 

Refer to the setup menu to learn how to set the starting address on this unit. The starting address of each 
unit is very important. Unfortunately it is impossible to tell you in this user manual which starting addresses 
you have to set because this completely depends on the controller you will use, the number of fixtures and 
their number of DMX channel they use. 

 

DMX-CONFIGURATION OF THE INTRUDERIN 7, 11, 16 AND 21CH MODE: 

 

EASY  STD  EXT  HSI 

Function 

Value 

PAN 

000-255 

CH7 is set to 000-005 

TILT 

000-255 

CH7 is set to 000-005 

Dimmer (0 - 100%) 

000-255 

  

open 

000-004 

  

Normal strobe slow to fast 

005-125 

  

open 

126-134 

  

Random strobe slow to fast 

135-255 

  

 

Summary of Contents for INTRUDER

Page 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 INTRUDER...

Page 2: ......

Page 3: ...W RGBW LEDs are driven at 30W for excellent cooling and long lasting performance of the LEDs Color LCD display for easy menu navigation 3p XLR connectors for DMX in and output PowerCon compatible powe...

Page 4: ...perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid...

Page 5: ...ed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and mac...

Page 6: ...o browse the menu Select the desired function with the ENTER button Use buttons to change the mode or value Once the required mode or value is selected press the ENTER button to select Level 1 Level 2...

Page 7: ...und activates sound controlled effects Master activates master mode Once the correct option shows on the display press the ENTER button to confirm Fixture Pan Invert Used to select if the PAN movement...

Page 8: ...cess the different functions in the menu Press the buttons until the desired function is showing on the display Press the ENTER button A list with all the functions will appear Press the buttons to se...

Page 9: ...ojector Press the MENU button to access the different functions in the menu Press the buttons until the desired function is showing on the display Press the ENTER button the display shows the firmware...

Page 10: ...pin is more popular because these cables are compatible with balanced audio cables Pin layout XLR 3pin Pin1 GND Pin2 Negative signal Pin3 Positive signal To prevent strange behavior of the light effec...

Page 11: ...r 000 255 7 Dimmer fine 000 255 7 8 7 Strobe 000 003 Closed 004 010 Open 011 103 Strobe slow to fast 104 107 Open 108 207 Pulse strobe slow to fast 208 212 Open 213 225 Random strobe slow 226 238 Rand...

Page 12: ...visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order t...

Page 13: ...er consumption 280 Watt max Fuse 250V 5A Slow blow 20mm glass Power connections Lockable Power Connector 10A Neutrik PowerCon compatible DMX connections 3pin XLR male female DMX channels used 7ch 11ch...

Page 14: ......

Page 15: ......

Page 16: ...st for the latest product news FR Inscrivez vous notre liste de distribution si vous souhaitez suivre l actualit de nos produits NL Abonneer je vandaag nog op onze mailinglijst en ontvang ons laatste...

Reviews: