ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
3/4
FX-1200
OPERATING INSTRUCTIONS
Put the fogger on a flat and very stable surface. Make sure that nobody can put their hands just in front of
the output. The fog is very hot and can cause serious burnings!!!
Make sure the fog liquid tank is not empty.
Always use good quality fog liquid to fill up the tank. Close
the tank immediately to prevent dirt to enter the reservoir!
Plug the supplied remote in the remote control input on the back of the unit.
Make sure to plug the fogger in a mains wall socket with earth connection
Switch the fogger on and wait for about 5 minutes. (warm up time)
Please note that the fogger is ready when the green LED of the wired
controller is lit.
Used with the supplied wired remote controller:
Connect the special 5pin connector of the controller to the [MANUAL
CONTROLLER] input on the back of the fogger.
For as long as the green LED (1) is on, you can press the button (2)
at any time to produce fog.
Used with the supplied wireless remote controller:
Connect the special 5pin connector of the wireless remote receiver to
the [WIRELESS CONTROLLER] input on the back of the fogger.
Fix the remote receiver with its magnetic surface to the fogger.
Pull out the antenna of the wireless remote controller and press any of the 4 buttons to produce fog.
MAINTENANCE
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Cleaning the fogger:
To prevent obstructions in the heater, pump and tubes, the fogger should be cleaned on a regular basis:
every 100h of continuous operation is a good reference.
Switch the fogger off
Remove the nozzle (metal part where the fog leaves the fogger)
Remove the fog liquid from the tank
Fill the tank with about 1liter of a solution containing 80% distilled water and 20% white vinegar.
Switch the fogger on and wait for about 8minutes (warm up time)
Put the fogger in continuous operation mode until the tank is empty
Put the nozzle back in place
Remove the eventual residues of the cleaning solution and refill the tank with fog liquid.
Remark:
cleaning should be done outside; an awful smell is produced by the vinegar solution!
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!