EZ-SPOT15 WW OUTDOOR

 

OVERHEAD RIGGING 

Important:

 

The  installation  must  be  carried  out  by  qualified  service  personal  only.  Improper 

installation  can  result  in  serious  injuries  and/or  damage  to  property.    Overhead  rigging  requires 
extensive experience! Working load limits should be respected, certified installation materials should 
be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below  the installation place  is free from unwanted persons  during rigging, de-rigging 

and servicing. 

  Locate  the  fixture  in  a  well  ventilated  spot,  far  away  from  any  flammable  materials  and/or  liquids.  The 

fixture must be fixed 

at least 50cm

 from surrounding walls. 

  The device should be installed out of reach of people and outside areas where persons may walk by or be 

seated. 

 

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s 
weight. 

  Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. 

This  secondary  safety  attachment  should  be  installed  in  a  way  that  no  part  of  the  installation  can  drop 
more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

 

Don’t cover any ventilation openings as this may result in overheating.  

  The operator has to make sure that the safety-relating and machine-technical installations are approved by 

an expert before using them for the first time. The installations should be inspected every year by a skilled 
person to be sure that safety is still optimal. 

 
 

ELECTRICAL INSTALLATION 

Important:  The  electrical  installation  should  be  carried  out  by  qualified  personal  only, 
according to the regulations for electrical and mechanical safety in your country. 

 

 
 

OPERATING INSTRUCTIONS 

 

 Just connect the projector to the mains. 

 Press the [ON] button on the IR-4 remote control for 3s. The LED will flash 2 times. 

 The IR remote control is now ready for use. 

 Pressing the [OFF] button for 3s will disable the IR remote control. The LED will flash 2 times. 

 Pressing the [OFF] button shortly will switch off the output of the projector. 

 

 

 

 