ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
8/11
CLUBWASH
ELECTRICAL INSTAL ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Every time you turn the unit on, it will show [
“
Led-RGBUYu
”] on the display and move all the motors to their
‘home’ position and you may hear some noises. After that the unit will be ready to receive DMX signal or run
the built-in programs.
YOU CAN OPERATE THE UNIT IN TWO WAYS:
o
By master/slave built-in preprogram function
o
By universal DMX controller (5CH, 9CH and 15CH DMX mode)
•
BY MASTER/SLAVE BUILT-IN PREPROGRAM FUNCTION:
Select this function when you want an instant show. By linking the units in master/slave connection, the
first unit will control the other units to give an automatic, sound activated, synchronized light show. Its DMX
input will have nothing plugged into it
. The display will indicate “Sh 1, … Sh 4”.
Important! This function only works when the blackout mode in the menu of the master is set to
“no”, otherwise nothing will happen! Read more about this option in the “Main Menu” paragraph.
•
MASTER has 4 built-in shows:
You can select
show 1
,
show 2
,
show 3
or
show 4
directly in the
menu of the master.
•
SLAVES have 2 working options:
The other units are set to slave mode. In order to create a great
light show you can introduce contrast movements (pan/tilt of slave is inversed)
→
In the menu of the
slave units you can go to option “
SLMd
” and select:
o
“SLA1”
→
Normal slave:
slave works in sync with the master.
o
“SLA2”
→
2 light show:
slave works in opposite with the master.
HOW TO CONNECT THE UNIT BY DMX
The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You
need to “daisy chain” your DMX controller and all the connected light effects with a good
quality XLR M/F balanced cable. To prevent strange behavior of the light effects, due to
interferences, you must use a 90Ω to 120Ω terminator at the end of the chain. Never use Y-
Electrical installation for several units on a DMX line: