21
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
With the nipple of the lamp facing the back insert one end of the
lamp into the socket. Pull up the spring of the other side of the
socket and snap the other end of the lamp into place.
Remove the knurl nut on both ends of the lamp.
The knurl nuts are not required with this kind of lampholder.
There is a small milled recess on each end of the lamp. Make sure
it fits correctly into the socket.
If changing the lamp, remove old lamp from
lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb.
Insert the new lamp in the lamp socket.
1
3
2
milled recess
2.1 Installing or changing the lamp
WARNING: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
2. Installation
Position head in horizontal position. Hinge no. 1 must be on the
upper side of the head. Turn screws no. 5 1/2 turn left and remove
plastic lid.
Loosen knurled head screw no. 3 and open the lampcover
.
Light source: OSRAM HMI 1200W/S
Install a 3-prong gounding type plug that fits your supply
Connected load: voltage 230V, frequency 50Hz, Power 340 VA
WARNING: To ensure propper installation of the plug consult a qualified
technician!
2.2 Powering the fixture
brown live “L”
blue neutral “N”
yellow/green gound
Summary of Contents for VARYSCAN 7