31
Varyscan
®
4 1200 HMI
DIP-switch position: DIP-switch No.2 switch 2
off
, switch 3
on
3. JB-lighting 6 channel drive mode
channel 1
x-motor
channel 2
y-motor
channel 3
gobo
channel 4
colour
channel 5
dimmer/shutter
channel 6
iris/gobo rotation
DIP-switch position: DIP-switch No.2 switch 2 and 3
on
Reset on DMX:
DIP-switch No.2 switch 4
If you would like to reset your Varyscan
®
from your DMX-desk, turn switch 4
on
at DIP-switch No.2. Now you have the
possibility to reset your Varyscan
®
, if you transmit DMX-factor 255 via gobo channel.
If switch 4 at DIP-switch No.2 is turned
off,
reset on DMX is not possible.
Adjustment of DMX-addresses
:
DIP-switch No.1 switch 1-9
Depending on the optional drive mode, you have to adjust DMX-addresses as follows. The addressing works by a binary
numeral system and in 6 channel drive mode it has to follow in six steps.
Varyscan
®
Nr.
DMX address
Dip switch setting
1
1
2
7
3
13
4
19
5
25