32
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein T49 (0)7304-9617-0
5.3 Clean fixture
5.2 Lamp replacement
see chapter 2.1
To ensure a long and satisfying performance of the fixture, check function of the fans
in the head and in the base from time to time. Most important: make sure that there is no
dust or fluff covering the air inlets.
To clean the fixture open lid of the head and the baseplate. Use a brush and a vacuum
cleaner to remove dust and fluff. Don´t damage or bend any parts.
Incompetend performace of the maintenance will invalidate the warrany claims. Consult
qualified service personnel.
ACHTUNG: Gerät vom Netz trennen und mindestens 30 Minuten abkühlen lassen !
For a maximum light output the optical system has to be cleaned from time to time.
Loosen the screws holding the top cover of the head and remove the plastic lids of
both sides of the head.
Remove lamp before cleaning the optical parts of the fixture.
Use a soft cloth and gently whipe reflector, lenses and colour filters. You also may
use a pair of tweezers and a regular glass cleaner.
5.4 Cleaning the optics
WARNING: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
electronic ballast