7.1 Service menu
RESET FIXTURE
Upon the “Reset” command, P12 Wash will initialise to its initial values. It is the same procedure
as after switching on the P12 Wash. If an error message appears in the display, this could be the
first step to correct it.
ERROR LIST
The P12 Wash stores all occurring errors internally. An error message can have a harmless cause.
If you experience frequent error messages, please contact your dealer or the JB-Lighting service
department. All error messages are displayed with the respective frequency and can be deleted.
FUNCTION TEST
This function allows you to test all functions of the P12 Wash without using a light mixer. The
pan/tilt reset is deactivated in the process.
DMX TEST
This menu item is used to test the DMX input. Use the function keys to select the DMX channel
to be tested. The display shows the incoming value, at the same time the P12 Wash reacts ac-
cordingly.
INIT PAN TILT
The P12 Wash is calibrated in the pan/tilt position at the factory. If it loses this calibration, i.e. it
strikes against the stop or no longer finds its position, it can be re-initialised using this function.
This process takes about 3-4 minutes and ends with a reset of the spotlight.
DISPLAY CONTRAST
The contrast of the LCD display may change when the temperature is too high. In this menu item
the contrast can be adjusted.
FINE ADJUST
The FINE ADJUST area is protected by a key combination. Focus, shapers, shaper rotation, pan
and tilt are calibrated at the factory. If there are large deviations in the calibration between the
individual headlights, this can be corrected in the FINE ADJUST menu. For more information
please contact our service.
IDENTIFY DEVICE
The RDM command IDENTIFY DEVICE can be called up or deactivated via this menu item.