The menu informs you about the current software/firmware version. The non-resettable
counter displays total hours of use since the JBLED A7 was
manufactured.
Temperature readouts from the display panel (
) and power supply unit
(
) in the base as well as the driver (
) and LED PCB
(
) in the head are available. In each case, you can view the current
temperature and the maximum temperature reached since the readout was last reset
individually.
TOT OPERATE TIME
TEMP BASE LCD
TEMP BASE PS
TEMP HEAD DRV
TEMP HEAD LED
4.6 Standalone mode
A sequence, up to 20 steps, consisting of preprogrammed cues can be recalled by means
of the
. The sequence will run as a loop. Cues can be entered in two
different ways. The first way is to program every feature by means of the key of the units
onboard control panel. The second way is to program the cues by means of a connected
DMX control console and to store them in the fixture.
IMPORTANT
STANDALONE MODE
!
The functions
,
and
can be accessed only by pressing a combi-
nation of keys and not just by pressing "ENTER". Before activating the functions make
sure that there is just one DMX-transmitter in the DMX-line (e.g. one controle console or
one master fixture). A number of DMX-transmitters can damage the DMX driver of the
fixtures. To enter the functions press “ENTER” (keep it down) and press "ESC" in addition.
MODIFY RUN
REMOTE
Programming the standalone sequence:
Enter the menu
will be displayed.
Enter the
menu to get access to the fixtures functions. Recall the functions and
enter DMX values.
Enter
(during which the effects will move to the programmed position)
Enter
which will be the duration of the step.
Add a new step with
The DMX values of the last step will be automatically copied
to the new step.
With
one step of the sequence can be deleted. Chose the step and confirm the
function with ENTER.
To reset the DMX values of a step use
. Select the step and confirm with
“ENTER”. All DMX values of the step will be set on zero.
With
the complete sequence will be deleted and the display will show
STANDALONE, EDIT.
STEP NR 01/01
MODIFY
FADE TIME
NEXT TIME
INSERT.
DELETE
RESET STEP
CLEAR ALL
STEP 01/01.
COOLING MODE
The JBLED A7 offers three different modes for fan opperation. The default setting
will suit most applications. Switch to
to reduce the speed of the fans
to a minimum. This mode is to be used only a well ventilated rooms with low ambient
temperature, with reduced light output or if the fixture is only required occasionally. The
mode is designed to be used in areas with higher air temperature or for fixed
installtions. The fans start to run faster with more airflow which produces more noise.
There is in no mode danger for the lifetime of the JBLED A7. If the temperature rise to
much the fixture switches off automatically.
STANDARD
SILENT
HI POWER