3.3 DMX wiring
The JBLED A7 has 3pin and 5pin XLR connectors for DMX-in and DMX-out.
Do not connect more than 1 data input an 1 data output on a fixture.
Connect the DMX-out of the control desk to the first JBLED A7 in line. (lighting control
desk DMX-Out / JBLED A7 DMX-In). Connect the second JBLED A7 to the first in line,
and so on (JBLED A7 2 DMX-In / JBLED A7 1 DMX-Out). All 3-pin and 5-pin connectors
are wired parallel.
Do not use this fixture as a DMX splitter!
The DMX-Out of the last unit in line is not occupied unless problems occur.
Then use a termination plug with the last JBLED A7 in line.(XLR-connector with a 120
Ohm resistor soldered between pin 2 and pin 3). Problems might occur when the line is
overloaded, e.g.
4
2
3
4
2
3
5
1
5
1
Use a shielded twisted-pair cable with two pairs to connect the serial link. Connect
all pins if you want to upgrade the software in crossload.
If a microphone cable (or any other cable with only one pair) is used the software
can not be updated via DMX line because pin 4 and 5 are not connected.
Pin assignment
Pin 1 = shield
Pin 2 = data -
Pin 3 = data +
Pin 4 = data out -
Pin 5 = data out +
shielded signal cable
3.4 Installing a plug on the power cord
Install a plug like described in chapter 2.1.
Connected load: Voltage 100-240 Volts, frequence 47-63 Hz, power 350 VA
Connect the fixture to a proper installed grounded system only. If any doubts on the
electrical installations occur, consult a qualified electrician. In case of damages occuring
due to a not proper installed electrical system, warranty claims will be invalidated. Don´t
use fixtures when top cover is not fixed properly. Contact with electronic parts can result
in risk for life.
Connect fixture only after assuring that the electrical installation fits your demands. If any
doubts occur consult a qualified technican!
(
)
Electrical shock 100-240 V
WARNING:
JBLED A7 might light up immediately if standalone mode is active or
DMX signal is connected!
!