57
6.4 Verifying electronic devices
In
accordance
with
the
applicable
German
safety
regulations
(Accident
Prevention
and
Insurance,
DGUV regulation3/regulation4
),
electrical
installation
and
equipment
have
to
undergo
inspection
at
regular
intervals.
For
this
purpose,
the
fixing
screw
of
the
5-pin
DMX
socket
may
serve
as
measuring
point
for
the
insulation
and
fault
current
measurement.
This
screw
is
connected
to
all
sheet
metal
parts
by
means
of
a
contact
disc.
PE-measuring point
6.3 Software update
To update the fixture via PC/Notebook, a Upgrade-Dongle (USB/DMX converter) with
software is required. The upgrade-dongle has to be connected to the fixture with a 5 pin
XLR connector. The software for the products is available from the JB-Lighting homepage
at www.jb-lighting.de
6.2 Cleaning the fixture
To ensure a long and satisfying performance of the fixture, check function of the fans in
the head and in the base from time to time. Most important: make sure that there is no
dust or fluff covering the air inlets. To clean the fixture open fan filter lid and the baseplate.
If the air filter in the head is full of dust, clean or replace it (spare part no. JBK0088). Use a
brush and a vacuum cleaner to remove dust and fluff. Don´t damage or bend any parts.
Incompetend performace of the maintenance will invalidate the warranty claims. Consult
qualified service personnel.
WARNING:
Disconnect fixture from mains, and allow unit to cool
down for at least 10 minutes!
With direct view on the beam source use a welding goggle of reduction 4-5!
ATTENTION: Débranchez l'appareil du secteur et le laissé refroidir au
moins 10minutes! Lors d'un regard direct dans la source lumineuse il est
fortement recommandé de porter une lunettes de soudeur équipée de
verres à vision atténué degré 4-5!
!
FINE ADJUST - zoom adjustment
The zoom effect in all A12 is calibrated at the factory. But if necessary it is possible to fine-
tune the zoom using the
ZOOM OFS
command.
RECEIVESOFT
command to prepare the A12 for a software upload. See 6.3
Software update and the uploader device documentation.
Use the
RECEIVE SOFT