3
JB INDUSTRIES
• PLATINUM OPERATING MANUAL • 800.323.0811 • [email protected] • JBIND.COM
PLATINUM
®
PUMP MODELS
PLATINUM
®
FLEX AC / BATTERY POWERED VACUUM PUMPS
DV-85-FLEX
DV-85-FLEX-AC DV-85-FLEX-BAT
DV-142-FLEX
DV-142-FLEX-AC DV-142-FLEX-BAT
CFM
3 CFM (85 l/m)
3 CFM (85 l/m)
3 CFM (85 l/m)
5 CFM (142 l/m)
5 CFM (142 l/m)
5 CFM (142 l/m)
MOTOR
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
VOLTAGE
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
Battery: 18v/20 VDC
Adapter: 115v/60Hz
230v/50Hz
INTAKE PORT
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
OIL CAPACITY
26oz (769cc)
26oz (769cc)
26oz (769cc)
21oz (621cc)
21oz (621cc)
21oz (621cc)
110V-18V AC ADAPTER:
DV-BP-AC
Included
Included
Not Included
Included
Included
Not Included
BATTERY: DV-BP-BAT
CHARGER: DV-BP-CHRG
Included
Not Included
Included
Included
Not Included
Included
BATTERY RUN TIME
Approximately 90
minutes when using a
9Ah battery
Approximately 90
minutes when using a
9Ah battery
Approximately 90
minutes when using a
9Ah battery
Approximately 60
minutes when using a
9Ah battery
Approximately 60
minutes when using a
9Ah battery
Approximately 60
minutes when using a
9Ah battery
PREMIUM PUMPS
DV-42N
DV-85N
DV-142N
DV-200N
DV-285N
CFM
1 5 CFM (42 l/m)
3 CFM (85 l/m)
5 CFM (142 l/m)
7 CFM (200 l/m)
10 CFM (285 l/m)
MOTOR
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
1/2 HP, 1725 RPM
VOLTAGE
115v/60Hz
115v/60Hz
115v/60Hz
115v/60Hz
115v/60Hz
INTAKE PORT
1/4"
1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
1/2" x 1/4" x 3/8"
OIL CAPACITY
26oz (769cc)
26oz (769cc)
26oz (769cc)
21oz (621cc)
21oz (621cc)
21oz (621cc)
SHIPPING DIMS
17-5/8" x 9-1/8" x 14"
17-5/8" x 9-1/8" x 14" 17-5/8" x 9-1/8" x 14" 17-5/8" x 9-1/8" x 14"
17-5/8" x 9-1/8" x 14"
WEIGHT
29lbs (13 2kg)
30lbs (13 6kg)
32lbs (14 5kg)
32lbs (14 5kg)
34lbs (15 4kg)
DUAL VOLTAGE AND SPARK-PROOF PUMPS
DV-42N-250
DV-85N-250
DV-142N-250
DV-200N-250
DV-200N-250SP
SPARK-PROOF
DV-285N-250
MOTOR
1/2 HP, 1725/1425 RPM 1/2 HP, 1725/1425 RPM 1/2 HP, 1725/1425 RPM 1/2 HP, 1725/1425 RPM 1/2 HP, 1725/1425 RPM 1/2 HP, 1725/1425 RPM
VOLTAGE
115v/60Hz, 230v/50Hz
115v/60Hz, 230v/50Hz
115v/60Hz, 230v/50Hz
115v/60Hz, 230v/50Hz
115v/60Hz, 230v/50Hz
115v/60Hz, 230v/50Hz
PLUG OPTIONS*
US/EU/UK/AU/BR
US/EU/UK/AU/BR
US/EU/UK/AU/BR
US/EU/UK/AU/BR
US/EU/UK/AU/BR
US/EU/UK/AU/BR
*Specify plug type when ordering; -250 for US, -250EU for EU, -250UK for UK.
PLATINUM
®
FLEX AC AND BATTERY
POWERED VACUUM PUMP
NOTE:
The JB Industries Platinum FLEX pump uses the same style pump cartridge
as the AC-powered platinum pumps Please follow the same instructions as the other
pumps in this manual The instructions below are specific to the JB Industries Platinum
FLEX battery powered pump
Operation
To operate the JB Industries Platinum FLEX battery powered pump, use only JB Industries
Lithium-ion battery packs (minimum 18v 9Ah) Alternatively, the JB Industries AC
adapter can be used to power the pump for extended periods or when a charged battery
is not available For best performance and run time, make sure to fully charge your JB
18v 9Ah battery prior to use Slide the battery into the motor housing connector until
the side release tabs “click” and lock the battery into place Press and hold the power
button to start the pump, press and hold it again to stop the pump The JB Industries
Platinum FLEX pump has a low-voltage circuit that includes a buzzer and red LED This
circuit will beep and flash the LED to notify the user that the battery is running out of
power A slow beep/flash indicates that the battery has less than 3 minutes of run time
remaining A fast beep/flash indicates that the battery has approximately 30 seconds of
run time remaining The Platinum FLEX pump has an internal check valve that will help
prevent loss of vacuum if the motor stops However, the best practice is to blank off the
isolation valve before the low-voltage circuit disables the motor The low-voltage circuit
will stop the motor when the battery is discharged to protect the battery from becoming
permanently damaged To remove the battery, pinch the side release tabs on the battery
and slide it away from the pump To resume running the pump, slide a charged battery
(or the AC adapter) in the motor housing connector and turn the pump back on Allow
the discharged battery pack to cool and then place it on the charger to recharge it
Battery
The JB Industries Lithium Ion battery has a charge indicator Press the button on the
battery to see the existing charge level Please read the user manual that was included
with your battery for more details
Battery Charging
Slide battery onto the charger to initiate charging Only charge the battery when the
temperature is between 41° (5°C) and 104°F (40°C) The JB charger will show a red
light while charging the battery, and will show a green light when charging is complete
It will automatically stop charging when the proper voltage is achieved to prevent damage
to the battery cells Please read the user manual that was included with your charger
for more details
AC Adapter
The JB Industries Platinum FLEX battery powered pump can be used with an AC adapter
This allows the pump to operate for extended periods without relying on battery power
To use the AC adapter, slide the adapter into the motor housing connector until the side
release tabs “click” and lock the adapter into place Plug the AC cable into an available
outlet Check to make sure there is a green light on the power brick Press and hold the
power button to start the pump, press and hold it again to stop the pump Please read
the user manual that was included with your AC adapter for more details
WARNING:
Do not remove the battery or AC adapter from the pump while it
is running Doing so may create a spark which could potentially cause a fire or
explosion