background image

 

Installation Guide  

 

12 

 

Unitronics 

 

Notes: 

6. 

The JZ20 built-in USB port may be used for programming. Add-on Modules are available 
by separate order for communication and cloning. Note that the USB port and an Add-on 
module cannot be physically connected at the same time. 
 

7. 

Add-on module JZ-PRG, with 6-wires communication cable 
(supplied in PRG kit 

– see the JZ-PRG Installation Guide) can be used: 

 - for programming 
 - to connect a modem 

8. 

Add-on module JZ-RS4 (RS232/485), with a standard 4-wire communication  
cable can be used: 
 - for programming  
 - to communicate with other devices (including modems/GSM) 

 

 - for RS485 networking. 
 

9. 

Add-on module MJ20-ET1 enables communication over 100 Mbit/s TCP/IP network: 

-

 

Programming/data exchange with Unitronics software; 

-

 

Data exchange via MODBUS TCP as Master or Slave.

 

Miscellaneous 

 

Clock (RTC) 

Real-time clock functions (date and time). 

Environmental 

 

Operating temperature 

0

 to 50

C (32

 to 122

F) 

Storage temperature 

-20

 to 60

 C (-4

 to 140

F) 

Relative humidity (RH) 

10% to 95% (non-condensing) 

Mounting method 

Panel mounted (IP65/NEMA4X) 

DIN-rail mounted (IP20/NEMA1) 

Dimensions 

 

 

 

 

Size  

147.5X117X46.6mm

"

5.807

  )

 X 

"

4.606  X 1.835"). See Note 10

 

Weight 

300 g (10.6 oz)

 

 

 

 

Notes: 

 

 

 

 

10. 

For exact dimensions, refer to Page 2.

 

Mount

i

ng 

 

Panel mounting  

Insert into cut-out: 117 x 89mm (WxH) 

4.606”x 3.504” 

DIN-rail mounting 

Snap unit onto the DIN rail 

 
 

 

 

 
 

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole 
discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or 

temporarily withdraw any of the forgoing from the market. 
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of 
merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in 
this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising 

out of or in connection with the use or performance of this information. 
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other 
third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them

 

 

  UG_JZ20-T1X_T20HS.pdf  

   09/22

 

Summary of Contents for JZ20-T10

Page 1: ...on Before using this product the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibi...

Page 2: ...r for communication and cloning Integral USB Port This may be used for programming purposes Note the USB port and an Add on module cannot be physically connected at the same time Add on during install...

Page 3: ...ing Controllers offering a terminal block with pitch of 5mm 26 12 AWG wire 0 13 mm2 3 31 mm2 Controllers offering a terminal block with pitch of 3 81mm 26 16 AWG wire 0 13 mm2 1 31 mm2 1 Strip the wir...

Page 4: ...known to be non hazardous Please note that it is recommended to back up all data retained in RAM in order to avoid losing data when changing the battery while the power is switched off Date and time i...

Page 5: ...al inputs If I0 I1 I4 are set as high speed counters without reset I2 I3 I5 can function as normal digital inputs 4 The following information concerns JZ20 T18 JZ20 J T18 and JZ20 J T20HS in addition...

Page 6: ...ust be connected Input wiring I0 I7 npn sink Input wiring I0 I7 pnp source Input wiring I0 I5 pnp source I6 I7 npn sink JZ20 J T20HS Note The inputs are arranged in two groups You can wire one group a...

Page 7: ...T20HS Unitronics 7 HSC input wiring npn sink HSC input wiring pnp source Shaft encoder wiring npn sink Shaft encoder wiring pnp source Digital Outputs Outputs Power Supply JZ20 T10 JZ20 J T10 JZ20 T1...

Page 8: ...l source Analog Input wiring current JZ20 T18 JZ20 J T18 JZ20 J T20HS only 2 or 3 wire AN0 AN1 4 wire AN0 AN1 Analog Input wiring voltage Note If either I6 or I7 is wired as an npn digital input the r...

Page 9: ...Logic 1 npn sink 17 28 8VDC for Logic 0 0 5VDC for Logic 1 I0 I5 I6 I7 Input current 3 7mA 24VDC 1 2mA 24VDC Response time 10mSec typical 20mSec typical Input cable length Up to 100 meters unshielded...

Page 10: ...ency 50Hz resistive load 0 5Hz inductive load 3kHz with resistance load 4k only O0 O2 in JZ20 J T20HS Short circuit protection Yes Short circuit indication Yes On voltage drop 0 5VDC maximum Power sup...

Page 11: ...d in the operating panel faceplate to custom label the keys and logo picture An extra logo slide is included A complete set of blank slides is available by separate order Program Ladder code memory 48...

Page 12: ...er to Page 2 Mounting Panel mounting Insert into cut out 117 x 89mm WxH 4 606 x 3 504 DIN rail mounting Snap unit onto the DIN rail The information in this document reflects products at the date of pr...

Reviews: