SECTION 9
PROPANE SYSTEM
tank OEM. If you have further questions,
consult your RV dealer, the OEM or Jayco
Customer Service.
The main shut off valve must be kept closed
at all times unless you are using the propane
system or filling the propane cylinder. When
the cylinder is disconnected from the hose,
install the valve cover that is attached so the
container. This is required by the National Fire
Protection Agency (NFPA), other applicable
local codes and for your own safety.
Close the propane cylinder main shut off
valve by hand tightening only. Use of tools
creates a potential to over tighten the valve
(damaging the interior seals on the cylinder
valve seat). If this type of damage occurs, the
cylinder will not close properly and create a
false sense of security.
The following label should be kept
permanently affixed to your RV.
Fig. 9.4 “Use propane only” label
Servicing or filling
Have the RV checked for leaks at the
connections on the propane system soon
after the purchase and the initial filling of each
propane cylinder. When you have a new
cylinder filled for the first time, make sure your
propane supplier purges your new tank of
trapped air. Otherwise, an improper mixture of
gas and air will make it impossible to light
your propane appliances.
When a propane tank is low, occasionally
there may be a concentration of an onion or
garlic-like odor, which can be mistaken for a
propane leak. After the propane tank has
been refueled, the odor will usually disappear.
If not, turn OFF each propane cylinder shut off
valve and have the propane system inspected
by your dealer or a qualified propane service
representative.
No one should be inside and only the qualified
propane service technician should be near the
RV while the propane tank is being filled. The
new propane tank must be carefully purged
for best performance and must
NEVER BE
OVERFILLED.
The following label should be
kept permanently affixed to your RV.
Fig. 9.5 “Shut off during re-fueling” label
Before entering a propane or fuel service
station make sure all pilot lights are
extinguished. Shut off gas to all appliances
by closing the propane gas main shut off
valve. Always shut OFF any engine before
refueling. Do not smoke and do not
operate other ignition sources while
refueling.
69
Summary of Contents for Melbourne 2011
Page 1: ...www jayco com Owner s Manual Model Year 2011 P N 0189568 2011 C L A S S C M O T O R H O M E ...
Page 25: ...SECTION 2 OCCUPANT SAFETY Fig 2 4 Propane alarm testing label 21 ...
Page 26: ...SECTION 2 OCCUPANT SAFETY 22 THIS PAGE IS INTENTIONALLY BLANK ...
Page 34: ...SECTION 3 PRE TRAVEL INFORMATION 30 THIS PAGE IS INTENTIONALLY BLANK ...
Page 46: ...SECTION 5 RV TIRES 42 THIS PAGE IS INTENTIONALLY BLANK ...
Page 54: ...SECTION 6 ELECTRICAL SYSTEM 30 AMP 50 THIS PAGE IS INTENTIONALLY BLANK ...
Page 70: ...SECTION 8 PLUMBING SYSTEM 66 THIS PAGE IS INTENTIONALLY BLANK ...
Page 80: ...SECTION 10 SLIDEOUT SYSTEMS 76 THIS PAGE IS INTENTIONALLY BLANK ...
Page 100: ...SECTION 12 STORAGE MAINTENANCE 96 THIS PAGE IS INTENTIONALLY BLANK ...