![background image](http://html1.mh-extra.com/html/jayco/embark-2022/embark-2022_owners-manual_3570511108.webp)
102
Section 8: Plumbing System
7. When the water tank is full:
Method 1:
Remove the water hose and replace the cap on the water tank.
Method 2
: Shut off pressurized water source, disconnect water source, and remove the
hose from the City Water inlet.
8.
Turn off power to the water heater. Switches are located in a bathroom cabinet. Bypass
the water heater. Sanitizer must be kept out of the water heater. Set the bypass valves
to the BYPASS position (two supply valves OFF, middle valve ON). The 3 valves are
located near the water heater.
9.
Turn Water Pump Backflow Valve ON (when using the pump).
10. Turn the pump switch ON.
11. Open the hot and cold water line faucets one at a time (kitchen, lavatory, shower and
outside shower) until water begins to flow continuously and a chlorine smell is notice
-
able. Close the hot and cold water faucets.
12. Turn the pump OFF.
13. Let the solution remain in the system for at least four hours when disinfecting with 50
PPM residual chlorine. If a shorter time period is desired, then a 100 PPM chlorine
concentration should be permitted to sit in the system for at least one hour. For com-
plete fresh water tank sanitization, driving your motor home for a short distance will
allow the sanitizing solution to splash around all sides of the tank.
14. After the required sanitization period, drain the chlorine solution from the fresh water
system (see
Draining the Fresh Water System
).
15.
Re-fill the fresh water tank. Verify that the city water valve is in the horizontal (fill
tank) position (Fig. 1). Refer to Step 6 above to fill the fresh water tank.
16. Turn water source OFF. Set the city water valve back to the vertical (city water) posi-
tion. Water source should attach to the City Water inlet. Turn the water source ON.
Water Pump Backflow Valve should be turned OFF. Open all faucets (including outside
shower) to flush all the water lines with fresh water (pump is not used for this). Water
heater bypass should still be set to BYPASS (to prevent water from entering the water
heater).
17. Drain the fresh water system again (see
Draining the Fresh Water System).
Re-fill the
fresh water tank with potable water. Turn the water heater bypass valves to the NOR-
MAL position (hot & cold supply valves ON, middle valve OFF) to allow water into the
Aqua-Hot water heater. Detach the outside shower hose.
The following steps must be done before flushing the system with the vinegar solution:
Water filter from the canister filter has been removed at the utility center.
Aqua-Hot water heater is bypassed before flushing the system with the vinegar
solution.
NOTE:
The shower hose must be connected to the outside shower.
NOTE:
If a chlorine taste lingers in the water, flush the water system
with a solution consisting of one-quart vinegar to five gallons of clean water.
Table of Contents
Maintenance Record
Summary of Contents for Embark 2022
Page 1: ...0311088 2022 2022 Owner s Manual Asubsidiary of Thor Industries Inc...
Page 2: ......
Page 6: ......
Page 20: ...14 Section 1 Warranty Service Notes Table of Contents Maintenance Record...
Page 30: ...24 Section 2 Occupant Safety Notes Table of Contents Maintenance Record...
Page 36: ...30 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 88: ...82 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Page 98: ...92 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record...
Page 122: ...116 Section 8 Plumbing System Notes Table of Contents Maintenance Record...
Page 132: ...126 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 142: ...136 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 152: ...146 Section 12 Interior Bathroom Water Heater Switches Table of Contents Maintenance Record...
Page 156: ...150 Section 13 Exterior Notes Table of Contents Maintenance Record...
Page 164: ...158 Section 15 Additional Information Notes Table of Contents Maintenance Record...