Section 5: Slideout Systems
81
6.
Press and hold the OUT button (Fig 4). To retract, press
and hold the IN button. There will be a slight delay before
the room begins moving.
7.
The GREEN LED should be solid ON when room is in
motion.
8.
Release the OUT button when the room is fully extended
or the IN button when fully retracted, and stops moving.
9.
Turn
OFF
the on/off switch or key.
Fault Diagnostics / Troubleshooting
The control has the ability to detect and display several faults. When a fault is detected,
room movement stops and two different LEDs will flash in a pattern.
The RED FAULT CODE LED (Fig 4) will flash a number of times corresponding to a spe
-
cific fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will flash GREEN a number of times cor
-
responding to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
MAJOR and MINOR faults
; faults must be cleared for the room to operate normally.
MINOR
faults can be cleared by pushing and releasing the
IN
or
OUT
buttons on
the wall touchpad (Fig 4).
MAJOR
faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).
NOTE:
For MAJOR faults, the control must be overridden by
following the EMERGENCY RETRACT MODE in the OVERRIDE
MODES section.
Summary of Contents for EAGLE FW HT 2020
Page 1: ...Owner s Manual 0283661 2020 2020 TT and HT Towables...
Page 2: ......
Page 4: ......
Page 12: ...10...
Page 26: ...Section 1 Warranty Service 24 Notes...
Page 44: ...Section 3 Pre Travel Information 42 Notes...
Page 72: ...Section 4 Vehicle Operation 70 Notes...
Page 118: ...Section 7 Fuel Propane System 116 Notes...
Page 176: ...Section 11 Electronics 174 Notes...
Page 186: ...Section 12 Interior 184 Notes...
Page 196: ...Section 14 Travel Camping Storage Checklists 194 Notes...