JAYCO TOWABLE SECTION 6 – ELECTRICAL SYSTEM
6-13
G
ENERATOR
(I
F
S
O
E
QUIPPED
)
The factory-installed generator will produce 120-volt AC power for use when camping in
areas where shore power is unavailable. 120-volt power from the generator is output to the
AC distribution center by way of a factory-installed automatic transfer switch. In the
default mode, the automatic transfer switch connects the generator to the AC distribution
center when the generator is operating and shore power is disconnected.
Be aware the generator, when operating, gives off carbon monoxide.
NOTE:
Refer to the manufacturer’s owner’s manual for detailed operating and safety
information.
Before starting the generator
1.
Make sure the carbon monoxide detector is working.
2.
Turn “off” air conditioners and all other appliances.
3.
Check for fuel, exhaust and coolant leaks.
STOP the generator immediately if there is a fuel, exhaust or coolant leak and have it
repaired!
To start the generator manually
1.
Press the operation control switch to start the generator. (Depending on how cold it
is, preheat can take up to 15 seconds).
2.
The hour meter will monitor minutes of usage when the generator is running.
WARNING
CARBON MONOXIDE IS DEADLY! Do not run the generator when your
recreation vehicle is indoors or in a confined space.
Asphyxiation or carbon
monoxide poisoning hazards exist whenever generator exhaust gasses can
accumulate.
WARNING
CARBON MONOXIDE IS DEADLY! MOVING PARTS AND ELECTRICITY
can cause severe personal injury or death. To reduce exposure to these hazards,
always disable AGS (if so equipped) before:
Sleeping in vehicle, unless vehicle has a working CARBON MONOXIDE
detector.
Parking vehicle in garage or confined space.
Parking vehicle for storage.
Servicing vehicle for storage.
Servicing generator.
Servicing batteries.
Servicing appliances or electrical systems.
Fueling the generator.
DO NOT run the generator or use the AGS AUTO ON or QUIET ON modes (if
so equipped) when your RV is indoors or in a confined space
. Asphyxiation or
carbon monoxide poisoning hazards exist whenever generator exhaust gasses can
accumulate.
Summary of Contents for 2016 White Hawk
Page 1: ...2016 WHITEHAWK 0221524 2016 PRINTED ON RECYCLED PAPER Generations of family fun TOWABLES...
Page 2: ......
Page 4: ......
Page 10: ...TABLE OF CONTENTS WHITE HAWK TRAVEL TRAILERS VI Revised 12 30 15...
Page 26: ...SECTION 1 WARRANTY SERVICE JAYCO TOWABLE 1 16 NOTES...
Page 36: ...SECTION 2 OCCUPANT SAFETY JAYCO TOWABLE 2 10 NOTES...
Page 46: ...SECTION 3 PRE TRAVEL INFORMATION JAYCO TOWABLE 3 10 NOTES...
Page 142: ...SECTION 13 EXTERIOR JAYCO TOWABLE 13 6 NOTES...
Page 150: ...SECTION 15 ADDITIONAL INFORMATION JAYCO TOWABLE 15 4 NOTES...