SECTION 5-SLIDEOUT SYSTEMS JAYCO TOWABLE
Error Codes
During operation when an error occurs, the board will use the LEDs to incidate where the
problem exists. For motor specific faults the green LED will brlink 1 time for Motor #1
and 2 times for Motor #2. The red LED will blink from 2 to 9 times depending on the
error code:
Error codes are as follows:
2 times
Battery drop out: Battery capacity low enough to drop below 6 volts while
running.
3 times
Low Battery: Voltage is below 8 volts at the start of a cycle.
4 times
High Battery: Voltage is greater than 18 volts.
5 times
Excessive Motor Current: High amperage, also indicated by 1 side of the slide
continually stalling.
6 times
Motor Short Circuit: Motor or wiring to motor has shorted out.
8 times
Hall signal not present: Encoder is not providing a signal. Usually a wiring
problem.
9 times
Hall Power Short to Ground: Power to encoder has been shorted to ground.
Usually a wiring problem.
When an error code is present, the board needs to be reset. Energizing the extend / retract
switch will reset the board. Energize the extend / retract switch again to go back to normal
operation.
Troubleshooting Information
Checking Fuses:
Schwintek Inwall Slide requires a minimum 30 Amp fuse. Check the Load Center for
blown fuses and replace any if necessary. If the fuse blows immediately upon
replacement, there is a problem with the wiring to the Inwall Slide control box. A
qualified service person should be called to check and repair.
Obstructions:
Check outside the RV for possible obstructions: tree, post, car etc… Check inside the RV
for any obstructions: luggage, furniture, open cabinets, etc… Also check for smaller
objects that may be wedged under the floor or in the sides of the unit. Remove
obstructions before proceding.
Error Codes:
Refer to error codes explained previously along with instructions on how to locate the
Inwall Slide Controller.
Low Voltage:
The Schwintek Inwall Slide Controller is capable of operating the room with as little as 8
volts. But at these lower voltages the amperage requirement is greater. Check the voltage
at the controller. If voltage is lower than 11 volts, it is recommended that the battery be
WARNING
DO NOT MOVE THE RV UNLESS THE MOTORS ARE PLUGGED IN TO
THE CONTROLLER AND THERE IS BATTERY POWER TO THE RV.
THIS SETS THE BRAKES ON THE SLIDEOUTS TO PREVENT THEM
FROM MOVING DURING TRANSIT.
5-5
Summary of Contents for 2016 North Point
Page 1: ...2016 NORTH POINT TOWABLES PRINTED ON RECYCLED PAPER Generations of family fun 0263154 2016...
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents North Point Fifth Wheel THIS PAGE IS INTENTIONALLY BLANK VI...
Page 26: ...JAYCO TOWABLE SECTION 1 WARRANTY SERVICE THIS PAGE LEFT INTENTIONALLY BLANK 1 16...
Page 42: ...JAYCO TOWABLE SECTION 3 PRE TRAVEL INFORMATION THIS PAGE LEFT INTENTIONALLY BLANK 3 8...
Page 58: ...JAYCO TOWABLE SECTION 4 TOWING SET UP THIS PAGE LEFT INTENTIONALLY BLANK 4 16...
Page 114: ...JAYCO TOWABLE SECTION 8 PLUMBING SYSTEMS THIS PAGE LEFT INTENTIONALLY BLANK 8 26...
Page 118: ...JAYCO TOWABLE SECTION 9 HEATING COOLING THIS PAGE LEFT INTENTIONALLY BLANK 9 4...
Page 144: ...SECTION 15 ADDITIONAL INFORMATION JAYCO TOWABLE NOTES 15 3...
Page 146: ...SECTION 15 ADDITIONAL INFORMATION JAYCO TOWABLE THIS PAGE LEFT INTENTIONALLY BLANK 15 5...