1) Set the function switch to the
position.
2) Insert the black lead plug into the COM jack and the
red test lead plug into the positive jack.
3) Press the MODE button until "
"
appears on the
display.
4) Touch the test probe tips to the circuit or wire you
wish to check.
5) If the resistance is less than 50
Ω
, an audible signal
will sound. The display will also show the actual
resistance measured between 0
Ω
and 399.9
Ω
DIODE TEST
WARNING:
To avoid electric shock, disconnect
power to the unit under test and discharge all
capacitors before taking any diode measurements.
1) Set the function switch to the
position.
2) Insert the black test lead into the COM jack and the
red test lead into the jack.
3)
Press the MODE button until " " appears on the
display.
4) Touch the test probe tips to the diode or