Jaycar Electronics XC0349 Instruction Manual Download Page 8

 

29 

 

LOW BATTERY INDICATOR 

The low battery indicator of the weather station and the transmitter will be displayed at the 
second section, and the low battery icon for the rain sensor (optional) will be display on the 
last section of the LCD respectively when the battery power is low. It is recommended to 
replace the batteries in all units on an annual basis to ensure optimum accuracy of the 
system. 

 

Note: 

 

After battery change, both the Weather Station and the transmitters need to be reset 
(see note ”

Setting up

”) 

 

The History data record will be clear after the battery change. 

 

OUTDOOR TRANSMITTER 915 MHz RECEPTION CHECK 

The outdoor temperature, humidity, wind data are transmitted from thermo-hygro 
transmitter every 4.5 seconds; the rainfall data are transmitted from the rain sensor 
(optional) every 6.25 seconds. The receiver will be synchronized to the thermo-hygro 
transmitter and rain sensor (optional) then. The transmission range (supposedly up to 
about 330 feet /100 meters) of the thermo-hygro transmitter/ rain sensor may be affected 
by the ambient temperature. At cold temperatures, the transmitting distance may be 
decreased. Please keep this in mind when placing the transmitter and the rain sensor. 

 

If (1) the outdoor data are not being received within first several minutes after setting up; 
(2) the outdoor display always show “- - -“ on the outdoor display; or (3) the reception icon 
of thermo-hygro transmitter (Mode 1) and rain sensor (optional) (Mode 2) is not displayed 
on the display, user shall check the following points: 

 

1. 

The distance of the Weather Station or transmitter/ rain sensor should be at least 5 
to 6.5 feet (1.5 to 2 meters) away from any interfering sources such as computer 
monitors or TV sets. 

2. 

Avoid positioning the Weather Center onto or in the immediate proximity of metal 
doors or window frames. 

3. 

Using other electrical products such as headphones or speakers operating on the 
same signal frequency (915 MHz) may prevent correct signal transmission and 
reception. 

4. 

Neighbors using electrical devices operating on the 915 MHz signal frequency can 
also cause interference. 

5. 

“Visibility” of weather center and transmitters increases the range 

 
 
 
 
 

 

30 

 

Note: 

When the 915 MHz signal is received, do not re-open the battery compartment cover of 
either the transmitter/ rain sensor or Weather station, as the batteries may spring free from 
the contacts and force a false reset. Should this happen accidentally then reset all units 
(see 

Setting up

 above) otherwise transmission problems may occur. 

During normal operation, after the outdoor display shows "- - -", the weather station will 
change to receive the outdoor data every 15 minutes, until the data is read. Then the 
reception period for thermo-hygro transmitter will return to 4.5 seconds (6.25 seconds for 
rain sensor - optional). 

 

If no reception is possible despite the observation of these factors, all system units have to 
be reset (see 

Setting up

). 

 

POSITIONING: 

Prior to permanently affixing any of the units, please ensure the following points are 
considered: 

 

Cable lengths of the units meet with your distance requirements at the point of fixing 

 

Signals from the sensors can be received by the base station at points of mounting 

 

La Crosse Technology Sensor Extension Cable 

You can purchase a La Crosse Technology Extension Cable if you require additional 
length to properly mount your sensor. The extension cable is 32 feet in length and comes 
with the appropriate connecter attached. Please visit your local retailer or 
www.lacrossetechnology.com and click on the Buy button to locate an online dealer or 
other retailers. 

 

Using phone cables or connections may damage your sensors because phone cables and 
connections have more resistance than the La Crosse Technology phone extension cable. 
Phone cables or connections are not recommended for use. 

 

Note:

 Using extension cables will shorten battery life. 

 

Warning:

 Never cut, splice, shorten or modify your sensor cables or extension cables. 

Doing so may damage your sensors and will void your warranty. 

 

The Weather Station 

The Weather Station has been designed to be hung onto wall or free standing with the two 
kinds of foldout stand. 

 
 
 

 

31 

 

To wall mount 

Choose a sheltered place. Avoid direct rain and sunshine. 
Before wall mounting, please check that the outdoor temperature 
and humidity values can be received from the desired locations. To 
wall mount: 

 

1. 

Fix a screw (not supplied) into the desired wall, leaving the 
head extended out the by about 5mm. 

2. 

Hang the station onto the screw. Remember to ensure that it 
locks into place before releasing. 

 
 
 
 
 

The Thermo-hygro Sensor 

 
 
 
 
 
 
 
 
 
 
 
 
 
An ideal mounting place for the thermo-hygro sensor would be the outer wall beneath the 
extension of a roof, as this will protect the sensor from direct sunlight and other extreme 
weather conditions. 

 

To wall mount, use the 2 screws to affix the wall bracket to the desired wall, plug in the 
thermo-hygro sensor to the bracket and secure both parts by the use of the supplied screw 
and ensure that the cables from the wind and rain sensors are correctly plugged in 
otherwise data transmission errors could occur.

 

 
 

Rain Cover

Main Unit

Wall Bracket 

 

32 

 

The Wind Sensor 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Firstly, check that the wind-cups can rotate freely before fixing the unit.  For correct and 
accurate readings, it is important to mount the sensor so that the front (marked E) is 
pointing in East-West direction.  The wind sensor should now be mounted using the screw 
or cable tie provided onto a solid wall/ panel mast or mast to allow the wind to travel 
around the sensor unhindered from all directions (ideal mast size should be from diameter 
0.62” to 1.29” (16mm to 33mm). Do not over tighten. 
Once the wind sensor is fixed onto the mast, connect the cable to the corresponding 
thermo-hygro sensor socket so that operating power supply can be received and data can 
be transmitted to the base station. Secure cord from blowing. Do not use staples. Using 
PVC pipe or metal as a mast may cause static. Wood is recommended. 

 

The Rain Sensor (optional) 

 
 
 
 
 
 
 
 
 

 

Wind -cups

Horizontal panel 

Vertical 
mast 

Horizontal panel 

Summary of Contents for XC0349

Page 1: ...IT with mounting bracket 3 Instruction Manual INSTANT TRANSMISSION is the state of the art new wireless transmission technology INSTANT TRANSMISSION offers you an immediate update every 4 5 seconds 6...

Page 2: ...in from step 2 5 The transmitter reception icon is now blinking again to indicate that the station is trying to get the rain sensor data It will stop blinking once the rain sensor has been detected If...

Page 3: ...KEYS Weather Station The Weather Station has 4 easy to use function keys Figure 1 Figure 2 Figure 3 11 SET key Press and hold to enter manual setting modes LCD contrast Manual time setting 12 24 hour...

Page 4: ...SPLAY SETTING The time can be set to view as 12 hour or 24 hour format The default time display mode is 12h To set to 24h time display 1 Use the or MIN MAX key to toggle the value 2 Confirm with the S...

Page 5: ...means that the air pressure has dropped and the weather is expected to get worse but not necessarily rainy Note After setting up readings for weather forecasts should be disregarded for the next 48 6...

Page 6: ...of recording of the history records you shall manually set the current time as soon as installing batteries to the weather station Afterwards you should avoid changing the pre set time as it will also...

Page 7: ...key to show the desired weather data For instance if you want to reset the minimum humidity in the normal display you shall press the MIN MAX key three times to show the min humidity value 2 Press an...

Page 8: ...to permanently affixing any of the units please ensure the following points are considered Cable lengths of the units meet with your distance requirements at the point of fixing Signals from the senso...

Reviews: