background image

 

17 

 

RELATIVE PRESSURE REFERENCE VALUE SETTING 

Note: 

The default reference pressure value of the barometer is 29.91inHg (1013 hPa) when 
batteries are first inserted. 

For an exact measurement, it is necessary to first adjust 

the barometer to your local relative air pressure (related to elevation above sea 
level)

. Ask for the current atmospheric pressure of your home area (Local weather service, 

www, optician, calibrated instruments in public buildings, airport). 

 

The relative air pressure can be manually set to another value within the range of 27.14 to 
31.90 inHg (919 to 1080 hPa) for a better reference. 
 
 
 
 
 
1. 

The current relative pressure value will start flashing 

2. 

Use the + or MIN/MAX key to increase or decrease the value. Keep holding the key 
will allow the value to increase faster. 

3. 

Confirm with the SET key and enter the 

WEATHER TENDENCY THRESHOLD 

VALUE SETTING

 

Note: 

This calibration facility is useful for those users living at various elevations above sea level, 
but wanting their air pressure display to be based on sea level elevation. 

 

WEATHER TENDENCY THRESHOLD VALUE SETTING

 

 
 
 
 
 
 
 
 
 
 
You may select a definite switching sensitivity value, .06, .09, or .12 inHg (2-4 hPa) for the 
change in the display of weather icons. This represents the "sensitivity" of the weather 

Flashing 

Flashing 

 

18 

 

forecast (the smaller the value selected, the more sensitive the weather forecast).  The 
default value is 0.09 inHg (3 hPa). 
1. 

The threshold value will start flashing 

2. 

Use the + or MIN/MAX key to select the value. 

3. 

Confirm with the SET key and enter the 

STORM WARNING THRESHOLD VALUE 

SETTING

 

STORM WARNING THRESHOLD VALUE SETTING

 

You may also define a switching sensitivity value for the Storm warning display at a 
decrease of air pressure from .09 inHg to .27 inHg (3-9 hPa) over 6 hours (Default 0.15 
inHg (5 hPa)). 
 
 
 
 
 
 
 
 
 
1. 

The threshold value will start flashing. 

2. 

Use the + or MIN/MAX key to select the value. 

3. 

Confirm with the SET key and enter the 

STORM ALARM ON/ OFF SETTING

 

STORM ALARM ON/ OFF SETTING 

Note: the storm alarm ON/OFF setting is not available on this model. Skip and exit 
this setting by pressing the SET key. 
 

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting anytime during the manual setting modes, press the HISTORY 
key anytime or wait for the automatic timeout. The mode will return to the normal time 
display. 
 

WEATHER FORECAST AND WEATHER TENDENCY 

 

WEATHER FORECASTING ICONS 

Weather icons in the third section of LCD can be displayed in any of the following 
combinations: 

Flashing 

 

19 

 

 
 
 
 

                        

      

 

 

 

 

 

 

For every sudden or significant change in the air pressure, the weather icons will update 
accordingly to represent the change in weather. If the icons do not change, then it means 
either the air pressure has not changed or the change has been too slow for the Weather 
station to register. However, if the icon displayed is a sun or raining cloud, there will be no 
change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) 
since the icons are already at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better or worse and not 
necessarily sunny or rainy as each icon indicates. For example, if the current weather is 
cloudy and the rainy icon is displayed, it does not mean that the product is faulty because 
it is not raining. It simply means that the air pressure has dropped and the weather is 
expected to get worse but not necessarily rainy. 

 

Note:

 

 

After setting up, readings for weather forecasts should be disregarded for the next 48-60 
hours. This will allow sufficient time for the Weather station to collect air pressure data at a 
constant altitude and therefore result in a more accurate forecast. 

 

Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather 
forecasting feature is estimated to have an accuracy level of about 75% due to the varying 
areas the Weather station has been designed for use. In areas that experience sudden 
changes in weather (for example from sunny to rain), the Weather station will be more 
accurate compared to use in areas where the weather is stagnant most of the time (for 
example mostly sunny). 

 

If the Weather station is moved to another location significantly higher or lower than its 
initial standing point (for example from the ground floor to the upper floors of a house), 
discard the weather forecast for the next 48-60 hours. By doing this, the Weather Station 
will not mistake the new location as being a possible change in air-pressure when really it 
is due to the slight change of altitude.  
 

WEATHER TENDENCY INDICATOR 

Working together with the weather icons is the weather tendency indicators (located on the 
left and right sides of the weather icons). When the indicator points upwards, it means that 

Sunny 

Cloudy with sunny intervals 

Rainy 

 

20 

 

the air-pressure is increasing and the weather is expected to improve, but when indicator 
points downwards, the air-pressure is dropping and the weather is expected to become 
worse. 

 

Taking this into account, one can see how the weather has changed and is expected to 
change. For example, if the indicator is pointing downwards together with cloud and sun 
icons, then the last noticeable change in the weather was when it was sunny (the sun icon 
only). Therefore, the next change in the weather will be cloud with rain icons since the 
indicator is pointing downwards. 

 

Note:

 

 

Once the weather tendency indicator has registered a change in air pressure, it will remain 
permanently visualized on the LCD. 

 

AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH 
BAROMETRIC PRESSURE TREND) 

The bottom section of the LCD also shows the relative air pressure value and the air 
pressure history. 
Depending on programming conditions, display of the history of air pressure in form of a 
graph consisting of vertical bars. 
The bar graph of the electronic barometer shows the air pressure history of the past 12 
hours in five 3-hour steps. 
 
 
 
 
 
 
 
The horizontal axis represents the last 12 hours air pressure recording (-12, -9, -6, -3 and 
0 hour). The bars are plotted at each of the 5 steps and give the trend over the recorded 
period. The scale on the right compares the result. The "0" in the middle of this scale 
determines the current air pressure. 

 

The vertical axis represents the air pressure changes in inHg (+0.12, +0.06, 0, -0.06, -0.12.  
The “0” represents the current air pressure). The newly measured pressure was compared 
to the previously recorded pressure reading. The pressure change is expressed by the 
difference between the current ("0h") and the past readings in division of ±2 hPa or ±0.06 
inHg. If the bars are rising it indicates that the weather is getting better due to an increase 
in air pressure. If the bars go down it indicates a drop of the air pressure and the weather 

Air pressure

changes in inHg

Air pressure 
changes in hPa 

Summary of Contents for XC0349

Page 1: ...IT with mounting bracket 3 Instruction Manual INSTANT TRANSMISSION is the state of the art new wireless transmission technology INSTANT TRANSMISSION offers you an immediate update every 4 5 seconds 6...

Page 2: ...in from step 2 5 The transmitter reception icon is now blinking again to indicate that the station is trying to get the rain sensor data It will stop blinking once the rain sensor has been detected If...

Page 3: ...KEYS Weather Station The Weather Station has 4 easy to use function keys Figure 1 Figure 2 Figure 3 11 SET key Press and hold to enter manual setting modes LCD contrast Manual time setting 12 24 hour...

Page 4: ...SPLAY SETTING The time can be set to view as 12 hour or 24 hour format The default time display mode is 12h To set to 24h time display 1 Use the or MIN MAX key to toggle the value 2 Confirm with the S...

Page 5: ...means that the air pressure has dropped and the weather is expected to get worse but not necessarily rainy Note After setting up readings for weather forecasts should be disregarded for the next 48 6...

Page 6: ...of recording of the history records you shall manually set the current time as soon as installing batteries to the weather station Afterwards you should avoid changing the pre set time as it will also...

Page 7: ...key to show the desired weather data For instance if you want to reset the minimum humidity in the normal display you shall press the MIN MAX key three times to show the min humidity value 2 Press an...

Page 8: ...to permanently affixing any of the units please ensure the following points are considered Cable lengths of the units meet with your distance requirements at the point of fixing Signals from the senso...