Jaycar Electronics QC8602 User Manual Download Page 14

Chapter 3 Operation Instruction 

Note: Analog speed dome does not support operations through menu; all the functions are invoked or 
configured by special presets.   

3.1 Power-on Action 

After power is turned on, device will perform self-test action that begins with lens motion, then horizontal 
motion and finally vertical motion. After power-on self-test action, the interface as shown in following Figure 
will be displayed. Analog camera’s interface (related with camera) is shown as the Figure3.1, including address, 
baud rate, parity bit, data bit, stop bit. The start-up interface will disappear after 40 seconds.   

   

Figure 3.1 Analog Speed Dome Startup Picture 

Lens motion: 

Lens zoom in and out, and then close iris. Iris keeps closed until motor action finishes.   

Horizontal motion: 

Dome turns clockwise first and then counter-clockwise after it detects zero position. It will 

stop after a short trip.   

Vertical motion: 

camera will begin with slow downward motion. After reaching contact point, it will move up 

quickly and stop at 45

o

.  

3.2 Basic Function Guide 

The following operation shall be done in collaboration with backline control device or client software. Control 
devices include control keyboard and DVR, etc. Client software is the software on customer’s end. Examples 
are given here for common operation only with assumption that the current control system supports following 
operation. Please refer to Client Software User Manual for detail operation guide. 

Horizontal and vertical motion: 

move the joystick toward the expected direction, or press 

Up/Down/Left/Right buttons.   

Lens zooming operation: 

press 

TELE

 button to pull the lens closer and the scene will be bigger. Press 

WIDE

 

button to pull the lens farther and the scene will be smaller.   

Focusing operation: 

After FAR button is pressed, the object far away will become more legible and the object 

in vicinity will become ambiguous. After NEAR button is pressed, the object in vicinity will become more 
legible and the object far away will become ambiguous.   
Under auto focus mode, camera will focus automatically to maintain legible Figure. Now, manual focusing 

12 

 

Summary of Contents for QC8602

Page 1: ...Integrated Intelligent Speed Dome User Manual V 1 0 1...

Page 2: ...ON 5 2 3 INITIAL SETTING 8 2 4 SWITCH SETTING 9 CHAPTER 3 OPERATION INSTRUCTION 12 3 1 POWER ON ACTION 12 3 2 BASIC FUNCTION GUIDE 12 3 3 PRESET POINTS FUNCTIONS 13 APPENDIX A LIGHTNING AND SURGING PR...

Page 3: ...eral devices to one power adapter as adapter overload may cause over heat or fire hazard 4 Please make sure that the plug is firmly connected on the power socket 5 When the product is installed on wal...

Page 4: ...hall be kept from rain and moisture 5 Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger 6 Please use the...

Page 5: ...othly and quietly the images have no vibration 1 2 Build in Integrated Camera Auto focus Auto back light compensation Auto white balance tracking Auto day and night functionality depending on the came...

Page 6: ...porates zooming effect Proportional Zooming Vertical and Horizontal scan speed will be changed during zoom time as speed down if zoom out and speed up if zoom in to get better monitoring performance I...

Page 7: ...When remove the camera pull the hook locks at the two sides of the camera with two hands and drag out the camera at the same time Removing the camera expose the speed dome chassis shown in Figure 2 1...

Page 8: ...SW2 on on Figure 2 4 Dial up switches on the profile of the camera 4 Install the dome cover Open the joint interface on the cover pull the wire twisted in the bracket into the dome cover through the...

Page 9: ...n the camera shown in figure 2 8 to the APRAGAZ sockets on the dome chassis shown in figure 2 7 Plug the camera into the cover with the guide arc along with the guide pillar on the chassis until you w...

Page 10: ...flange of transparent cover shown in figure 2 9 at the hook lock on the cover shown in figure 2 10 Finally fasten the two fixing screws on the two sides Figure2 9 The transparent lower dome casing Fig...

Page 11: ...This speed dome Self adaptive Pelco P Pelco D and HIK Code protocols 2 4 1 Device address setting SW1 is used to set device address as follow Device address Dialing setting schematics 1 2 3 4 5 6 7 8...

Page 12: ...OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON...

Page 13: ...for specific baud rate is listed as below SW2 baud rate switch setting Baud rate Dialing setting schematics 1 2 3 2400 ON OFF OFF 4800 OFF ON OFF 9600 ON ON OFF 19200 OFF OFF ON 38400 ON OFF ON 2 4 3...

Page 14: ...reaching contact point it will move up quickly and stop at 45o 3 2 Basic Function Guide The following operation shall be done in collaboration with backline control device or client software Control...

Page 15: ...l preset and is reserved Refer to chapter 3 3 3 3 Preset points functions 3 3 1 Analog speed dome special preset function Analog integrated speed dome can only be operated by preset and all the operat...

Page 16: ...Auto scan path 3 Close camera configuration Close parity and Verification 84 Clear all presets information 85 86 Auto scan path 4 87 88 89 Auto scan path 5 90 91 No 2 auto scan Start auto scan path h...

Page 17: ...se Sensor Up for SONY camera 45 Auto focus Half auto focus 46 Open park action Auto park action 10s 47 Close park action Auto park action 30s 48 Preset 1 Auto park action 60s 49 Preset 2 Auto park act...

Page 18: ...ith movement limitation the speed is adjustable If don t set the movement limitation it moves continuously It support park action as well and park action time is optional from 10s to 300s There are 6...

Page 19: ...duction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be appended The design for installation and wiring...

Page 20: ...s 800m When using thin communication wire or using the products in strong electromagnetic interference environment or many devices are connected on the bus the maximum length should become shorter acc...

Page 21: ...e likely to use star connection in practice at this time match resistance should be connected at the two devices that most apart In figure four those are device one and device 15 But as this connectio...

Page 22: ...matched between Host and the Speed Dome 1 Adjust the address or Baud Rate of Host or Speed Dome to make a match 2 RS485 are connected incorrectly 2 Change the RS485 and RS485 wires 3 Wiring drops 3 fa...

Page 23: ...oltage wastage rate is below 10 the recommended maximum transmission length is as follows For the AC power supply device the biggest voltage wastage rate is 10 For example a device with 80VA rated pow...

Page 24: ...Appendix D Wire Gauge Comparison List Home and Abroad 22...