background image

Receiving your CoolAire Unit

Locate and remove the screws securing the 

box to the skid. Lift and save the box incase 

a return is necessary. Remove the strapping 

and unpack the unit. Inside the tank locate 

the following:

1)  Atomizing Fan Head
1)  Column Assembly
1)  Operators Manual/Service Bag

UNPACKING

4

PICTURE OF A

BOXED  UP  COOLAIRE 

UNIT ON A SKID

WHEN AVAILABLE

SETUP

Carbon Fiber 

Column (installed)

Lower Hand Hold

Upper Hand Hold

Atomizing Fan Head

Set Up

- Locate your CoolAire unit on a level surface.
- Secure the front wheel locks.
- Install the carbon fiber column and secure 

(with thumb screw) at the bottom.
 - Grab the two hand holds on the atomizing 

fan head and lift atomizing fan head into 

position allowing the solid (gray PVC) plug to 

slip inside the carbon fiber tube. Align the 

dowel pin to fall into the milled slot.
- Secure in place with the second (yellow) 

thumb screw provided.

 

Summary of Contents for CoolAireMist COOL-101

Page 1: ...OPERATOR S MANUAL Read Understand Retain for Future Reference NOTICE Mobile Mist Cooler COOL 101 COOL 102...

Page 2: ...Notes Purchase Date Model ID Number Vendor Information...

Page 3: ...t would likely void the warranty and any manufacturer s responsibilities THE COOLAIRE MIST CAN BE AUTOMATED WHEN USED IN CONJUNCTION WITH A CONTROL THE FAN MAY NOT APPEAR POWERED BUT COULD SUDDENLY BE...

Page 4: ...st must be properly grounded as a precaution against possible electric shock Check for correct voltage supply Keep cord away from heat oil sharp edges and moving parts Replace damaged cords immediatel...

Page 5: ...A SKID WHEN AVAILABLE SETUP Carbon Fiber Column installed Lower Hand Hold Upper Hand Hold Atomizing Fan Head Set Up Locate your CoolAire unit on a level surface Secure the front wheel locks Install t...

Page 6: ...Connector Power Control Switches Sweep Adj Thumb Screw Oscillator Oscillator Control Box WARNING GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIONAL CODE NOTICE ALWA...

Page 7: ...ates a clogged flow restrictor tube Remove clean or replace Sump pumps can go bad if operated for lenghty periods of time out of water If the pump has little to no output flow Replace as needed If the...

Page 8: ...t Valve Fluid Level Switch If replacing either part Make sure to use thread tape in addition to pipe sealant to ensure a leak proof connection Oscillator If replacing an oscillator motor or a major co...

Page 9: ...r detail Load In Load Out coil N coil 115 VAC Load ON AUTO Shut off 2 4 5 1 3 8 6 5 3 1 2 4 CoolAire Electrical Schematic 230 VAC 50 Hz 1 Ph 230V osc motor oscillator locking switch osc light 230 VAC...

Page 10: ...oat Valve 721 In line Strainer 748 1 4 Turn Ball Valve 400 016 SST Flow Restrictor Tube 823 Drain Plug 793 Tank Parts Part No Push Handle Carbon Fiber 824 Tank Lid 825 Tank prepped w holes 749 P Servi...

Page 11: ...nce or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURING INC S LIABI...