OUTPUT TERMINALS
TAPE END OUT Terminal
X
During recording, when the end of the tape is reached
or when the tape counter reading indicates 7 hours 57
minutes or more, the output becomes 0V (Low).
X
To reset the output, press the STOP or EJECT button.
X
During autorepeat recording, when the end of the tape
is reached, the output becomes 0V (Low) for about 2
seconds only.
TAPE END OUT Terminal Output Setting
1
Press the MENU button until the (SET UP 3) menu is
displayed.
@@@@@@@<SET@UP@3>
*ALARM@MODE@@@@@@@Y1
*ALARM@DURATION@@@20S
*VERTICAL@SYNC@@@@Y
*EXT@TIME@ADJ.@@@@01:00
*TAPE@IN@MODE@@@@@STOP
*TAPE@END@MODE@@@@REW
*TAPE@END@OUT@@@@@-3M
*CLOG@DETECT.@@@@@Y
*SERIES@REC@IN@@@@N
2
Press the
*
(or
+
) button, until the “TAPE END OUT”
setting is flashing.
3
Press the
l
(or
j
) button, to select the desired
output mode.
–3M . . . . . . . The output becomes 0 V (Low)
when the tape counter reaches
“7
H
57
M
00
S
” and/or when the tape
reaches the end.
END . . . . . . . The output becomes 0 V (Low)
when the tape reaches the end.
4
Press the SEARCH button to save the setting.
WARNING OUT Terminal
X
If the tape stops or other problem, the output becomes
0V (Low).
X
To reset the output, press the STOP or ALL RESET
button or unplug the power cord then plug it back in.
NOTE:
X
If the output is 0V (Low) due to the clog detect function,
it can be reset by simply pressing the STOP button.
TIMER OUT Terminal
X
During timer recording DC 12 V (High) are output.
(During timer recording stand-by mode, the output is
0V (Low).)
COM Terminal
X
Common GND (ground) terminal when connecting
other terminals to external devices.
Tape end or 7
H
57
M
00
S
5V (H)
0V (L)
(Output impedance: 5.7 k
Ω
)
Output reset
Tape movement stop
5V (H)
0V (L)
(Output impedance: 5.7 k
Ω
)
Output reset
Timer recording
12V (H)
0V (L)
(Output impedance: 5.7 k
Ω
)
RC4QR/NAJV, NAJV2 (RTR5024, RTR5168 GB) Wed. June, 07/2000
English
35