background image

30/04/2018: DN 2020/08/24 

 

 

 
 
 
 
 
 

 

INSTALL BATTERIES

 

Remove screw located at rear end of unit and pull down hinged battery door to open. Always 
insert all 4 batteries into the compartment in the same direction. Note the polarity mark on the 
inside of the battery door for proper battery installation.

 

 

SENSOR

 

To Replace Sensor: Remove sensor by unscrewing sensor cover. Install the new sensor by 
aligning the notch in sensor socket with the raised tab on socket holder.

 

 

NOTE: 

Do not force sensor into socket. Misalignment can damage the sensor pins

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

4

 

PARTIAL LIST OF DETECTABLE GASES

 

METHANE

 

ACETYLENE

 

PROPANE

 

METHYL ETHER

 

ETHANE

 

AMMONIA

 

BUTANE

 

H. SULFIDE

 

HYDROGEN

 

INDUSTRIAL SOLVENTS

 

ETHYLENE

 

BENZENE

 

ETHANOL

 

ALCOHOLS

 

ISO-BUTANE

 

ACETONE

 

NOL

 

TOLUENE

 

GASOLINE

 

XYLENE

 

Summary of Contents for JAV-1090

Page 1: ...30 04 2018 DN 2020 08 24 JAV 1090 PROFIND COMBUSTIBLE GAS LEAK DETECTOR Safety Instructions Operation Manual Turvallisuusohjeet ja Käyttöohje FI ...

Page 2: ...gital display is independent from the audio alarm and sensitivity level allowing the precise pinpointing of the leak source The PROFIND does not require rechargeable batteries FEATURES Unique numeric leak size indicator Long life stable sensor Methane sensitivity 5 ppm Automatic calibration and reset to ambient Low battery indicator 3 adjustable sensitivity levels Audio mute function Uses 4 AA alk...

Page 3: ...UTE button To restore the audio sound press the MUTE button again Note a few seconds is required to restore sound if the mute button is pressed in rapid succession ADJUSTING SENSITIVITY LEVELS The Leak Detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on To change sensitivity levels press the SENS once for HI ...

Page 4: ...ry installation SENSOR To Replace Sensor Remove sensor by unscrewing sensor cover Install the new sensor by aligning the notch in sensor socket with the raised tab on socket holder NOTE Do not force sensor into socket Misalignment can damage the sensor pins 4 PARTIAL LIST OF DETECTABLE GASES METHANE ACETYLENE PROPANE METHYL ETHER ETHANE AMMONIA BUTANE H SULFIDE HYDROGEN INDUSTRIAL SOLVENTS ETHYLEN...

Page 5: ...ys ja herkkyystasosta mikä mahdollistaa vuotolähteen tarkan määrittämisen PROFIND ei vaadi uudelleenladattavia paristoja OMINAISUUDET Ainutlaatuinen numeerinen vuotokoon osoitin Pitkä käyttöikä vakaa anturi Metaaniherkkyys 5 ppm Automaattinen kalibrointi ja palautus ympäristön lämpötilaan Heikon pariston ilmaisin 3 säädettävää herkkyystasoa Äänen mykistystoiminto Käyttää 4 AA alkaliparistoa Luonno...

Page 6: ...miseksi paina MUTE painiketta Palauta ääni painamalla MUTE painiketta uudelleen Huomaa äänen palauttamiseksi vaaditaan muutama sekunti jos mykistyspainiketta painetaan nopeasti peräkkäin HERKKYYS ASETUKSEN SÄÄTÄMINEN Vuotoilmaisin käyttää oletuksena NORM herkkyystasoa automaattisesti kun yksikkö poistuu lämpenemisjaksosta ja vihreä LED syttyy Jos haluat muuttaa herkkyysastetta paina SENS kerran HI...

Page 7: ...Anturin vaihto Irrota anturi irrottamalla anturin kansi Asenna uusi anturi kohdistamalla anturin pistorasian lovi pistorasian kohotettuun kielekkeeseen LISÄTIETO Älä pakota anturia pistorasiaan Virheellinen kohdistus vahingoittaa anturin tappeja OSITTAINEN LISTA TUNNISTETTAVISTA KAASUISTA METAANI ACETYLEENI PROPAANI METYYLIEETTERI ETEENI AMMONIAKKI BUTAANI RIKKIVETY VETY TEOLLISET LIUOTTIMET ETYLE...